Datalogic PowerScan D8330 Краткое справочное руководство - Страница 2
Просмотреть онлайн или скачать pdf Краткое справочное руководство для Считыватель штрих-кодов Datalogic PowerScan D8330. Datalogic PowerScan D8330 2 страницы.
DEFAULT VALUES
USB-KBD DEFAULT SETTINGS
USA keyboard, FIFO enabled, inter-character and inter-code delays disabled,
USB keyboard speed normal.
: code identifier disabled, no field adjustment, code length not
DATA FORMAT
transmitted, no header, terminator = ENTER, character replacement disabled.
RS-232 Standard DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, delay disabled, rx
timeout 5 sec., ack/nack disabled, FIFO enabled, inter-character delay disabled,
serial trigger lock disabled.
: code identifier disabled, no field adjustment, code length not
DATA FORMAT
transmitted, no header, terminator = CR-LF, character replacement disabled.
WEDGE DEFAULT SETTINGS
USA keyboard, caps lock off, caps lock auto-recognition enabled, num lock
unchanged, inter-character and inter-code delays disabled, control character
emulation = ctrl+shift+key.
: code identifier disabled, no field adjustment, code length not
DATA FORMAT
transmitted, no header, terminator = ENTER, character replacement disable.
PEN DEFAULT SETTINGS
interpret operating mode, conversion to code 39 disabled, output level normal,
idle level normal, minimum output pulse 600 µs, overflow medium, inter-block
delay disabled.
CODE SELECTION
Enabled codes
•
EAN 8/EAN 13 / UPC A/UPC E without ADD ON
check digit transmitted, no conversions
•
Interleaved 2/5
check digit control and transmission, variable length code; 4-99 characters
•
Standard Code 39
no check digit control, variable length code; 1-99 characters
•
Code 128
variable length code; 1-99 characters
Disabled codes
EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, MSI,
Code 11, Code 16K, Code 49, GS1 DataBar™ Codes
TECHNICAL FEATURES
®
PowerScan
D8330/ D8330 AR
PowerScan®
Electrical Features
PowerScan® D8330
D8330 AR
4 to 30 VDC
Power Supply
Max. Consumption:
0.076 mm (3 mils)
0.25 mm (10 mils)
@ 4V
420 mA
500 mA
@5V
310 mA
370 mA
@30V
62 mA
70 mA
Sleep mode
4 mA
4 mA
Scan Rat
35 ± 5 scans/sec
Good Read LED (green)
Reading Indicators
Good Read Spot (green), Beeper
Optical Features
Reading Field
110 cm (43.3 in)
1090 cm (429.13 in)
(Typical performance at 20ºC /
@ 55 mils
@ 100 mils reflective
68ºF on high quality barcodes)
Max. Resolution
0.076 mm (3 mils)
0.178 (7,5 mils)
PCS (Datalogic Test Chart)
15%
25%
Laser Features
Power (max)
0.9 mW
1.3 mW
Scan Angle
42°
13.5° ± 0.7
Laser Safety Class
Class 2 EN 60825-1/CDRH
Environmental Features
Working Temperature
-30 °C to + 50 °C / -22° to +122 °F
-30 °C to + 70 °C / -22° to +158 °F
Storage Temperature
Humidity
90% non condensing
Drop Resistance
IEC 68-2-32 Test ED 2 m
Protection Class
IP65
Mechanical Features
Weight (without cable)
about 295 g (10.4 oz)
Cable Length
2 m (6 ft 6 in)
RESTORE DEFAULT
RESTORE DEFAULT
Ì$+$*oÎ
To change the defaults refer to the PowerScan® D8330/M8330 Reference
Manual, or to the Datalogic Aladdin™ Configuration program, both downloadable
from the website.
INTERFACE SELECTION
Select one of the interface codes according to your application.
USB INTERFACE SELECTION
USB-KBD
Ì$+UA03$-:Î
USB-KBD-ALT-MODE
Ì$+UA04$-@Î
USB-COM*
Ì$+UA02$-4Î
USB-IBM-Hand Held
Ì$+UA01$-.Î
USB-IBM Table top
Ì$+UA00$-(Î
USB KBD-APPLE
Ì$+UA05$-FÎ
* When configuring USB-COM, the relevant files and drivers must be installed
from the USB Device Installation software, which can be downloaded from the
web site http://www.scanning.datalogic.com.
PEN EMULATION INTERFACE SELECTION
PEN
Ì$+CP6$-BÎ
RS-232 INTERFACE SELECTION
RS-232 Standard
Ì$+CP0$-$Î
Nixdorf Mode A
Ì$+CM2EC0$->Î
Fujitsu
Ì$+CM1$-ÈÎ
ICL Mode
Ì$+CM0$-ÃÎ
WEDGE INTERFACE SELECTION
Wedge IBM AT or PS/2 PCs
Ì$+CP500$-aÎ
PC Notebook
Ì$+CP505$-ÈÎ
PC Notebook - ALT mode
Ì$+CP508$-2Î
IBM AT - ALT mode
Ì$+CP507$-+Î
Interface for IBM XT and IBM Terminals 3151, 347X and 348X can be selected
from the PowerScan D8330/M8300 Reference Manual available online at
http://www.scanning.datalogic.com.
KEYBOARD NATIONALITY
USB-KBD and Wedge users should select one of the following wedge keyboard
nationality codes according to the keyboard.
Belge
Ì$+FJ7$-8Î
Deutsch
Ì$+FJ3$-$Î
English
Ì$+FJ4$-)Î
Español
Ì$+FJ6$-3Î
Français
Ì$+FJ2$-ÊÎ
Italiano
Ì$+FJ1$-ÅÎ
Svenskt
Ì$+FJ5$-.Î
USA (Default)
Ì$+FJ0$-|Î
The following Keyboard Nationality selections are only valid for IBM AT compatible
PCs:
Japanese
Ì$+FJ8$-=Î
Russian (Latin)
Ì$+FJ9$-BÎ
Russian (Cyrillic)
Ì$+FJA$-jÎ
Hungarian
Ì$+FJB$-oÎ
Slovenian, Croatian, Serbian (Latin)
Ì$+FJC$-tÎ
Romanian
Ì$+FJD$-yÎ
Czech Republic
Ì$+FJE$-~Î
USING POWERSCAN® D8330/D8330 AR READERS
PowerScan® D8330 readers automatically scan barcodes at a distance. Simply
aim and pull the trigger. Code scanning is performed along the scan line emitted
from the reading window. This line must cross the entire code. The best reading
angles are indicated in the figure below.
AIMING SYSTEM
PowerScan® D8330 and PowerScan® D8330 AR provides an aiming system. If
enabled, a partial trigger press produces a red spot, which should be aimed over
the code center to get the best reading performance (see figure above,
completely pressing the trigger the scan line appears to start code scanning
After setting up the reader, you can enable or disable the aiming system by
reading the codes below:
Disable Aiming System (Default)
Ì$+Bj0$-"Î
Enable Aiming System
Ì$+Bj1$-'Î
DATA FORMAT TERMINATORS
For your convenience, some common Terminators are given below. For other
Header/Terminator selections, Data Format and Advanced Data Format
parameters, see the PowerScan® D8330/M8330 Reference Manual.
CR-LF
Ì$+EA120D0A$-ÃÎ
Enter
Ì$+EA1183$-0Î
Tab
Ì$+EA1184$-8Î
None
Ì$+EA10$-dÎ
OPERATING TEST
Read the TEST code below.
Code 128
t
e
s
t
). By
.