DIP Switches Settings Of Indoor Unit
The DIP switches are used to set the user code for each monitor.Total 6 bits can be config-
ured.
• Bit-1 to Bit-5 are used for user code setting. The value range is from 1 to 32, which have 32
different codes for 32 apartments.
• When multi monitors need to be installed in one apartment, these monitors should use the
same user code, and the master/slave mode should be set on the monitor.
• Bit-6 is bus line terminal switch, which should be set to "ON" if the monitor is at the end of
bus line, otherwise be set to "OFF".
ON
DIP
1
2
3
4
5
6
ON(1)
OFF(0)
O N
O N
=
=
Bit-6 switch setting
Bit state
Setting
When monitor is not
ON
DIP
at the end of bus line.
1 2 3 4 5
6
Bit state
Setting
When monitor is at
ON
DIP
the end of bus line.
1 2 3 4 5
6