Dataprobe IP-2810 Руководство - Страница 10

Просмотреть онлайн или скачать pdf Руководство для Переключатель Dataprobe IP-2810. Dataprobe IP-2810 13 страниц. Dual input web controlled power switches

iP-28xx
Direct Messaging Control
IP-815 allows direct computer control using simple ASCII strings. You can use this control technique either
through the serial port or via TCP/IP messaging. To access the iP-2815 over the network, open a connection on
port 9100. This technique works only when no none else is logged into the unit.
The command syntax is:
E
s
C
<Sec>
<n>
<Enter>
Turn On
Turn Off
Cycle Outlet
Query Status
Escape Code Responses
IP-2815 will confirm receipt of switching commands. The IP-2815 will report back:
<n> <status>
1 ON
2 OFF
3 ON CYCLE
4 ON
5 NONE
6 NONE
7 NONE
8 NONE
Escape Code Examples
Send Command
E
s
PASS1ON<enter>
C
E
s
PASS3C<enter>
C
E
s
PASS?<enter>
C
E
s
<Sec><n><Enter>
C
The Escape Character (Decimal 27 Hex 1B)
The Security Code (Default = PASS)
The Outlet Number
The Enter Key (Decimal 13 Hex D)
E
s
<Sec><n>ON<Enter>
C
E
s
<Sec><n>OFF<Enter>
C
E
s
<Sec><n>C<Enter>
C
E
s
<Sec>?<Enter>
C
Indicating the outlet (number 'n') has been changed. <status> will be ON, OFF, or
ON CYCLE or OFF CYCLE
The Query command returns the status of all 8 outlets:
iP-2815 Action
Turn On Outlet 1
Reset Outlet 3
Query Status
iP-2815 Response
1 ON
3 OFF CYCLE
1 ON
2 ON
3 OFF
4 ON
5 ON
6 OFF
7 ON
8 ON
Page 10