Dux Proflo 50S124P Руководство пользователя - Страница 10

Просмотреть онлайн или скачать pdf Руководство пользователя для Водонагреватель Dux Proflo 50S124P. Dux Proflo 50S124P 16 страниц. 25l and 50l electric storage water heater
Также для Dux Proflo 50S124P: Руководство пользователя (16 страниц)

Dux Proflo 50S124P Руководство пользователя
General:
This water heater is designed for single phase
230-240V a.c. supply only. The electrical
connection must comply with Local Supply
Authority Regulations and AS/NZS 3000.
Pre-Wired Models:
Water heaters with the letter "P" at the end of
their model number are factory fitted with a
power supply cord. These water heaters may
be plugged into a standard general purpose
power outlet.
If the power supply cord is damaged, it must
be replaced by the manufacturer, a service
agent or a similarly qualified person in order to
avoid a hazard.
"Hard Wired" Models:
Water heaters without the letter "P" at the end
of their model number are not factory fitted
with a power cord.
Connection of the electrical wiring must only
be carried out by a licensed tradesperson.
Before removing the electrical cover, ensure
the electrical power supply is safely isolated.
6
Owner's Manual – Proflo 25/50 Litre Water Heater

Electrical Connection

Connections are made at the terminal block
under the water heater electrical cover,
and a means for disconnection must be
incorporated in the fixed wiring in accordance
with the Wiring Rules.
The electrical cover may be removed by
undoing the two screws at the bottom of the
cover and sliding the cover downwards to
disengage the top edge.
Cable entry to the connection area is through
the hole in the case beneath the electrical
cover, designed to accept a 20mm conduit.
Ensure the conduit entry is well sealed to
achieve the correct weatherproofing.
When the supply wiring has been connected,
ensure the wires are kept lower than the
terminal block.
Before replacing the electrical cover, press the
reset button on the thermostat to ensure the
over-temperature energy cut-out is set.
Ensure the water heater is filled with
water before turning on the electricity
supply.
028299
Rev. C