Fluid Needle Replacement

As previously mentioned, the Platinum Pressure
Feed spray gun utilizes a universal fluid needle.
There is no need to change the needle when
changing fluid tips unless special self-cleaning
needles have been purchased. However, nee-
dles may wear over time, especially with very
abrasive coatings, and may need to be replaced
periodically.
NOTE: DUX offers optional self-cleaning fluid
needles for various coatings/applications.
These needles are specially designed to clean
material out of the fluid tip between triggering.
Due to the nature of these needles, they can
only be used with tips of the same size. Con-
tact DUX Customer Service for more informa-
tion regarding this option
5
The DUX Platinum Pressure Feed is provided with a brass trigger pin. This pin is manufactured from a
relatively soft metal to reduce wear on the Stainless Steel trigger.
Because it is a wearable part, it may be necessary to replace the trigger pin when heavy use of the gun
has resulted in deformation. When this occurs, it is best to replace the entire trigger pis-ton assembly,
since an excessively worn trigger pin may have caused unseen wear on other portions of the air valve.
For customer service call 888.389.2732
3
2
4
Figure 16: Exploded View of Fluid Needle Assembly
PLATINUM PRESSURE FEED
Removal of the fluid needle
1. Ensure the spray gun is depressurized
2. Unscrew the fluid control knob and com-
pletely remove the needle assembly.
3. Remove the needle cap (# 5 in Figure 16).
4. Remove the spring and needle from the fluid
control knob.
Replacement of the fluid needle
1.Install the new needle and spring into the fluid
control knob.
2.Carefully replace the needle cap making
certain the needle, needle holder, and spring are
properly seated.
3.Lubricate the needle as indicated in figure 2
and reinsert the needle assembly into the spray
gun body.
1
1.Fluid Control Knob
2. Needle Holder
3.Fluid Needle
4.Needle Spring
5. Needle Cap
Page 16