Warning: check nozzles and replace of worn
If pressure drops off, check nozzle for wear. Nozzles should be replaced on a regular basis (every
month for machines in regular use, every 3 months for machines used intermittently.
machine with the incorrect nozzle size or worn nozzle will void warranty and can be dangerous to the
operator.
UNLOADER SETTING
The high pressure unloader on the machine is factory set to operate the pump at it's rated pressure.
DO NOT ADJUST. Tampering with the unloader will void warranty and can be dangerous.

CARE AND MAINTENANCE:

AFTER EACH USE
If cleaning agents have been mixed with the incoming water, it is essential to flush the machine with clean water
after use.
If there is a danger of freezing anti-freeze should be mixed with the flush water or the machine must be
completely drained.
After the final flush stop the machine. DO NOT allow the machine to idle for more than 15 seconds. This is
particularly important when there is a danger of freezing. Do not run for longer without water supply.
STORAGE
Store the washer in an upright position, preferably drained of water if there is a danger of freezing (or fill with
anti-freeze).
PUMP CRANKCASE LUBRICATION
Proper pressure washer pump crankcase lubrication will help extend the working life of the machine. Follow
these important guidelines. We recommend keeping a simple service log book.
Change oil in pump after initial 50 hour run-in period. (SAE 75W-90)
,
Change pump oil every 3 months, use high quality oil. (SAE 75W-90)
,
Pump oil level can be checked with the dip stick under the breather cap or by viewing the oil sight gauge
,
where fitted. The oil level is correct if level is in the centre of the gauge. If oil level is low, fill to correct
level with recommended oil (SAE 75W-90). DO NOT OVERFILL CRANKCASE!
Replace oil in gearbox (separate chamber) with SAE 90 gear oil every three months.
,
PREVENTATIVE MAINTENANCE
Keep filter in supply hose connection clean, rinse regularly.
,
Use correct size nozzles for machine and replace when worn, check serial tag for correct size.
,
Drain water from pressure hoses, gun/lance assembly and accessories after use.
,
Protect pump from freezing. Failure to remove water from the pump in freezing temperatures will result in
,
damaged pump manifold.
Use ONLY injector of the size and type designed for this model.
,
DO NOT tamper with unloader valve adjustment or alter engine speed.
,
DO NOT siphon chemicals through the pump, it is designed for water only.
,
Incoming water supply must not exceed 60ºC, otherwise pumps seal damage could result
,
Follow engine manufactures guidelines for engine maintenance. (see engine manual)
,
6
Aussie Scud & Ultra ... Operation & Maintenance Manual
Feb 2012
Using the