The fwd parameter specifies reference #3 in the X.3 parameter list. This is the forwarding
condition (outside the PAD timer) which will forward data towards the X.25 virtual circuit. A value
of NONE indicates that there are no character forwarding conditions. A value of CR indicates that
a carriage return will forward any accumulated data (including the carriage return). A value of
ALL indicates that all data is to be forwarded immediately. The ALL option has the effect of
generating single user character X.25 packets on this virtual circuit.
The idle parameter refers to reference #4 in the X.3 parameter list. This is the time forwarding
condition. When it expires, it will forward any data collected to the X.25 circuit. The timer is reset
to the specified value whenever a forwarding condition is reached. The value is based on ticks of
th
1/20
of a second each per the X.3 specification.
The break parameter refers to reference #7 in the X.3 parameter list. This is the action to be
taken when a break indication (a standard telnet encapsulated value) is received from the remote
IP endpoint. The value of NONE will ignore the break, and it is deleted from the data stream. The
value of INTR will generate an X.25 interrupt packet. The value of RESET will generate an X.25
virtual circuit reset. The value of BRKIND will generate an X.29 "indication of break" message on
the X.25 virtual circuit.
The crlf parameter refers to reference #13 in the X.3 parameter list. This is the action to be taken
when a CR is received in the data stream from the remote IP endpoint. A value of NONE
indicates that there is to be no LF (line feed) insertion. A value of RMT will insert an LF following
a CR whenever it is sent towards the remote IP endpoint. A value of VC will insert an LF following
a CR whenever it is sent towards the X.25 virtual circuit. A value of BOTH will insert an LF
following a CR in either direction.
The inact option refers to the PAD inactivity timer. If enabled, the TCP session on that X.25
virtual circuit is disconnected when the inactivity timer expires. The value defaults to OFF.
2.3.8 D
M
ISPLAY
EASUREMENTS
Syntax: dmeas [link|vc <#>]
The dmeas command is only visible when the application is logged in. The command is used to
display the current measurements on either the X.25 link or per virtual circuit.
The LINK parameter will display the measurement information for the X.25 link being supported
by this instance of the application.
The VC <#> option will display the measurement information for a particular X.25 virtual circuit on
the link. The virtual circuit number is in the range of one through the maximum number supported
by the application.
2.3.9 V
C
ERIFY
ONFIGURATION
Syntax: vfy [link|vc <#>]
The vfy command is only visible when the application is logged in. The command is used to
display the configured options on the X.25 link, or a virtual circuit resident on the X.25 link.
The LINK parameter will display the configuration information for the X.25 link being supported by
this instance of the application.
The VC <#> parameter will display the configuration information for a particular X.25 virtual circuit
on the link. The virtual circuit number is in the range of 1 through the maximum number supported
by the application.