DVM International DVM-SA30IR Руководство
Просмотреть онлайн или скачать pdf Руководство для Дымовая сигнализация DVM International DVM-SA30IR. DVM International DVM-SA30IR 2 страницы.
Model: DVM-SA30IR
PRODUCT SPECIFICATIONS
Warranty period: Lifetime = 10 years.
After that, the smoke detector must be replaced.
Look for the production date on the sticker of the detector.
Power supply: Fixed Lithium battery 3 VDC (CR17450), battery not
interchangeable
Alarm Volume: >85dB (A) at 3 meters distance
Alarm Sensitivity: 0.10-0.16dB /m
Alarm Pause: About 8 minutes
Complies With: EN14604:2005/AC: 2008
Sound Pattern: ISO8201 (Beep 0.5s – Pauze 0.5s – Beep 0.5s – Pauze 0.5s – Beep 0.5s
– Pauze 1.5s while the red LED flashes. This pattern is repeated over and over
again.
Sound pattern of the wireless interconnection: Beep-Beep – Pause 1.2s. This pattern
is repeated over and over again.
DESCRIPTION
This is an optical smoke detector. These are particularly sensitive to detecting
visible microparticles (which arise from smoldering fires) and react faster than
ionization smoke detectors. An example of such smoldering fires is a burning
cigarette on a couch or bed, a common cause of devastating fires. Please note
that this device does not detect flames, temperature/heat, carbon monoxide or
other dangerous gases. The smoke detector has many advanced features and
a long service life with the fixed battery.
RECOMMENDED LOCATIONS FOR SMOKE
DETECTORS
1. Your smoke detector is suitable for the landing, hall, bedroom, living room and
dining room.
2. Install it in the stairwell and on each floor.
3. Smoke, heat and burning things spread horizontally after rising to the ceiling,
so install the alarm in the middle of the ceiling of a standard built house.
4. If for some reason the alarm cannot be installed in the middle of the ceiling,
the distance from the smoke detector to the wall should be at least 30 cm (see
Figure 1).
5. If the length of the room or hall is more than 10 meters, you need to install
several alarms there.
6. If the ceiling slopes, the smoke detector should be installed at least 50 cm from
the highest ceiling point in the room (see Figure 2).
Attention: This smoke detector is also suitable for installation in caravans, motor
homes and mobile homes.
30 cm
Ceiling
Figure 1
LOCATIONS TO AVOID
1. Avoid the environment of appliances or places where normal combustion
regularly takes place (such as in kitchens, near stoves, hot water boilers, etc.).
Use specialized smoke detectors, such as temperature detectors, for these areas
to prevent unwanted alarms.
2. Keep at least 3 meters away from rooms with high humidity, such as
bathrooms or rooms near dishwashers or washing machines.
3. Keep a minimum distance of 1 meter from air vents or ventilation openings for
heating and cooling. The air can blow away/suck away smoke from the
detector, preventing the detector from sounding the alarm (in time).
4. Avoid areas where the temperature may fall below 5°C or above 40°C.
5. Avoid extremely dusty or dirty environments. The dust particles prevent the
detector from functioning properly.
6. Also avoid the airflow of (loose) air conditioning units and fans.
ACTIVATE:
Press and hold the test button for about 3 seconds until the LED lights up. Then
release the test button within about 2 seconds. The smoke detector gives a beep
signal to indicate that it is activated and enters the working state.
WIRELESS INTERCONNECTION FUNCTION
1. Make sure all smoke detectors are activated.
Thank you for purchasing our smoke
detector. Take a few minutes to read the
user manual thoroughly and
familiarize yourself and your family
with how the smoke detector works.
And save it for future reference.
21
1116
DoP: RD-380D-HR-24-001
EN 14604:2005/AC:2008
Figure 2
1
© Copyright DVM International B.V.
2. Select one of the smoke detectors as the MASTER detector. Treat all other
smoke detectors as SLAVE detectors.
3. Press the master's test button three times within two seconds. The red LED
flashes quickly. The MASTER smoke detector is now in transmit mode for the
radio signal. This mode lasts 48 seconds.
4. While the MASTER smoke detector is in radio signal mode, press the test button
of a SLAVE detector three times within two seconds. The SLAVE detector stores the
signal from the MASTER detector and completes the pairing and gives a beep
with flash as confirmation.
5. Repeat the above steps on all other SLAVE detectors.
Clear wireless connection function
1. Determine which SLAVE detector should have the connection function
cleared.
2. Press the test button of the SLAVE detector three times within two seconds. The
red LED flashes quickly.
3. Press and hold the test button again until the red LED goes out the first time,
then release the test button immediately. The red LED will flash slowly.
4. Now press the test button again. The SLAVE detector beeps three times, which
means that the SLAVE detector has erased the wireless connection.
ATTENTION:
The smoke detector must first be activated, otherwise it will not work.
Thesmoke detector is designed to be wireless paired with up to 40 other smoke
detectors.
The smoke detectors are not designed to be paired with wireless detectors from
other series or manufacturers. The smoke detectors must first be connected to
each other in order to work in a coupled manner.
If one detector goes into alarm, all other, interconnected detectors, also go into
alarm. Only smoke detectors that are successfully linked can transmit the alarm.
If you clear the pairing, only the slave detector pairing is removed. The MASTER
detector cannot clear the link.
INSTALLATION:
WARNING: To prevent injury, the smoke detector must be securely
attached to the ceiling, as described below.
Installation drawing
DECKE
Tighten
OPERATION AND TESTING:
Testing
Press the test button. If the detector works correctly, the alarm will go off. If the
alarm does not go off, the battery is empty or the smoke detector is defective.
DO NOT USE an open flame to test your detector! You can use this to damage the
detector or cause a fire.
NOTE: Test the smoke detector every week!
Resting state:
The red LED flashes 1 time every 48 seconds to indicate that the smoke detector
is active.
Alarm state:
When the detector detects combustion products, it gives a sound alarm and the
red LED flashes once every second. The sound alarm and the flashing LED
continue until the air is clean again.
Boreholes
Mounting plugs
Screws
Unscrew
Smoke detector
Figure 3
2