Datexel DAT1112 Быстрый старт - Страница 3
Просмотреть онлайн или скачать pdf Быстрый старт для Передатчик Datexel DAT1112. Datexel DAT1112 4 страницы. Programmable range transmitter for thermocouple
DAT1112 PROGRAMMING INSTRUCTIONS
-
Version 1 (thermocouple K & J):
Sensor selection:
Sensor K:
SW1 ON
Sensor J:
SW1 OFF
SPAN PROGRAMMING
Sensor
Range
100 to 150°C
200 to 270°F
150 to 390°C
270 to 520°F
K
390 to 510°C
520 to 920°F
510 to 1400°C
920 to 2500°F
- Version 2 (thermocouple R & S):
Sensor selection:
It is not necessary because the transmitter is able to operate either with the thermocouple R or
the thermocouple S.
SPAN PROGRAMMING
Range
Sensor
650 to 940°C
1200 to 1720°F
R
940 to 1760°C
1720 to 3200°F
700 to 1010°C
1290 to 1850°F
S
1010 to 1760°C
1850 to 3200°F
ZERO PROGRAMMING:
It is not necessary. Zero could be adjusted from -50°C up to 50°C by the appositely dedicated
ZERO adjusting potentiometer.
- Version 3 (thermocouple T):
SPAN PROGRAMMING
Range
Sensor
100 to 145°C
210 to 290°F
T
140 to 450°C
280 to 840°F
ZERO PROGRAMMING:
It is not necessary. Zero could be adjusted from -50°C up to 50°C by the appositely dedicated
ZERO adjusting potentiometer.
SW4
SW2
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ZERO PROGRAMMING
Sensor
K & J
-100 to 15°F
SW1
SW2
ON
OFF
ON
OFF
OFF
ON
ON
OFF
SW4
SW3
ON
OFF
OFF
ON
SPAN PROGRAMMING
Sensor
J
Range
SW3
-50 to -10°C
OFF
ON
-10 to 50°C
OFF
ON
15 to 100°F
SW3
SW4
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
SW2
SW1
OFF
OFF
OFF
ON
Range
SW4
100 to 115°C
ON
200 to 210°F
115 to 290°C
ON
210 to 520°F
290 to 390°C
OFF
520 to 700°F
390 to 950°C
OFF
700 to 1700°F
SW2
OFF
ON
OFF
ON