1. Check the box contents *
The Aprisa SR+ Migration Station is shipped to you in a box containing
the following:
•
One Aprisa SR+ Protected Station containing two Aprisa SR+ radios pre cabled to the protection switch with product options of single
antenna operation and the power supply input of 48 VDC (part number suffix ends with AB)
•
One Aprisa SR+ Migration Switch with a power supply input of 48 VDC
•
Two cables TNC to TNC 160mm for RG142
•
Two cables N-male to -N-male 360mm for RG142
•
Two cables N-female- to TNC 800mm for RG142
•
Four rack mounting brackets and screws
•
One adaptor RJ45 to DB9 male and one adaptor RJ45 to DB9 female - MMS wired
•
One adaptor RJ45 to DB25 male and one adaptor RJ45 to DB25 female - MMS wired
•
Four 2 pin female power connectors
•
One 4 pin female remote control connector
2. Install the Aprisa SR+ Migration Station and connect the protection earths
The Aprisa SR+ Migration Station is designed to mount in a standard 19" rack.
The Aprisa SR+ Protected Station and the Migration Switch both have earth connection points on the bottom right of the chassis. Earth both
chassis earth connection points to a protection earth.
The antenna feeder cable should use grounding kits for lightning protection as specified or supplied by the coaxial cable manufacturer to
properly ground or bond the cable outer.
Note * When the spare Aprisa SR+ Migration Switch is supplied (APST-XMSW-450 or APST-XMSW-900), the item includes the Aprisa SR+ Migration
Switch chassis, 2x mounting brackets, 2x power connectors, RF cables and RJ45 to DB9 / DB25 adaptors.
Note: The Aprisa SR+ radio operates within frequency bands that require a site license be issued
by the radio regulatory authority with jurisdiction over the territory in which the equipment is
being operated. It is the responsibility of the user, before operating the equipment, to ensure
that where required the appropriate license has been granted and all conditions attendant to that
license have been met.
Hereby, 4RF Limited declares that the Aprisa SR+ digital radio is in compliance with Directive
2014/53/EU. The full text of the EU declaration of conformity is available at the internet address
http://www.4rf.com/library/en.
3. Connect the antenna and apply power to the Aprisa SR+ Migration Station
Connect the antenna to the Migration Station antenna port (TNC female connector). If the antenna is not available, terminate the TX/ANT A/B
antenna port with a TNC male 50 ohm terminator (10 Watts min). If the Migration Station is the dual antenna option, then both TX/ANT A/B
antenna ports / terminators must be connected.
Warning: Do not directly connect the two radio antenna ports without attenuation of at least 40 dB. The receiver can be damaged if signals
greater than +10 dBm are applied to the antenna port.
The Aprisa SR+ Migration Station has a power supply input of nominal 48 VDC (18 to 60 VDC floating) and consumes up
to 42 Watts. Four power connectors (Molex 2 pin female) are supplied fitted. Wire your power source to the four
power connectors (- / +), two for the Protected Station and two for the Migration Switch. The connector screws can be
fastened to secure the connectors.
Note: The radio fuses will blow if the connected power supply is over voltage, or the polarity is reversed. Spare fuses
are located on the Protection Switch board (see the 'Replacing Protection Switch Fuses' section of the Aprisa SR+ User
Manual and 'Replacing Migration Switch Fuses' section of the Aprisa SR+ User Manual Appendix 1 - Migration Station).
Turn your power source on. All the LEDs on both radios will flash orange for one second and then change to:
•
Active radio - the OK will light green, the TX / RX LEDs will light green (steady or flashing), the MODE and AUX LEDs will light green.
•
Standby radio - the OK will light green, the TX / RX LEDs will light green (steady), the MODE LED will light orange and the AUX LED
will light green.
4. Connect to the Aprisa SR+ Migration Station
Ensure that the Hardware Manual Lock switch is set to radio A (this is a factory default setting). This prevents random switching when changing
the radio settings.
The Aprisa SR+ primary radio (radio A) in the Migration Station has a factory default IP address of 169.254.50.10 and the secondary Aprisa SR+
radio (radio B) in the Migration Station has a factory default IP address of 169.254.50.20, both with a subnet mask of 255.255.0.0.
•
Set up your PC for a compatible IP address e.g. 169.254.50.1 with a subnet mask of 255.255.0.0.
•
Connect your PC network port to one of the Aprisa SR+ Migration Station Ethernet ports (1 to 4 depending on product option).
•
Open a browser and enter http://169.254.50.10.
Note: The Aprisa SR+ has a self signed security certificate which may cause the browser to prompt a certificate warning. It is safe to
ignore the warning and continue. The valid certificate is 'Issued By: 4RF-APRISA' which can be viewed in the browser.
•
Login to the primary radio with the default login 'admin' and password 'admin'.
•
Each radio in the network and both radios in the Migration Station must be setup with unique IP addresses on the same subnet.
Set the Primary IP address and the Secondary IP address to network compatible IP addresses. Set the Migration Station Virtual IP
Address. This is the IP Address of the active radio used in both bridge and router modes. Set the Subnet mask and Gateway.
If the IP addresses of radios in the Migration Station are unknown for some reason, they can be shown or changed via the Command Line
Interface (CLI) on the radios MGMT USB ports. USB to UART Bridge VCP Drivers are required to connect the radio USB port to your PC. You can
download and install the relevant driver from https://www.silabs.com/products/development-tools/software/usb-to-uart-bridge-vcp-drivers.
Set the PC serial port to 38,400 baud, 8 data bits, no parity and 1 stop bit, with no hardware flow control.
•
Open the Migration Station drawer by sliding it from the front
•
Connect your PC USB port to the primary Aprisa SR+ (A) MGMT USB port (see the Aprisa SR+ User Manual CLI section)
•
Login to the radio with the default login 'admin' and password 'admin'.
•
At the command prompt >> type 'cd APRISASR-MIB-4RF' and enter
•
At the command prompt >> type 'ls Terminal' and enter to show the existing IP address
•
At the command prompt >> type 'set termEthController1IpAddress xxx.xxx.xxx.xxx' and enter to change the IP address.