CookRite ATMG-36 Руководство по эксплуатации - Страница 8
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Гридл CookRite ATMG-36. CookRite ATMG-36 19 страниц. Gas countertop griddles
The equipment can only be placed on the incombustible counter top, and keep
adistanceatleast6inches(152mm)toequipment'sbothsidesandback,and keep a distance at
least 4 inches(102mm) to the bottom;
Donot put anything around the equipment, and on the counter top and bottom, in order
to avoid influencing combustion and air circulation; Leave enough distance in front of the
equipment to take apart the control panel. All major parts, in addition to the burner
remove from the front intake-tube;
It may be necessary to adjust the balance of air input by authorized and licensed
technicians;
Thread glue must be resistant to the action of liquefied petroleum gases. Warning! Use
soap water or testing instrument to test whether piping joint leaks or not before using,
and forbid using an open flame to test! After installing completely, you should check gas
supply
pressure.
typepressuregauge, theminimum value is 0.1mbar) or a digital pressure gauge to test.
Steps are as following:
●Remove top panel, and needle type pressure
joint screw arbor (Fig.1), then slip rubber tube
of pressure gauge over needle type pressure
joint;
●Start the equipment in accordance with the
instructions, measuring gas supply pressure
(dynamic pressure) in the work state;
●Access to the equipment if measured data within
the limits of Table 1, otherwise,
you will need to adjust gas pressure
regulating valve or contact gas supplier to bargain;
●Unplug pressure gauge after you accomplish pressure testing, then install needle
type pressure joint screw arbor. Important: make sure screw up the needle valve
to prevent gas escape!
6.2、Debugging
It's very important to debug the new stove. Through the comprehensive system test
of equipment, we can ensure function and safety performance of products. Discovering
any potential problems before use (such as equipment's placement, ventilation,
operation, etc), can avoid costly losses.
7. Safety Notices and Precautions
Warning! For your safety, do not place petrol and other flammables nearby.
Use
a
pressuregaugewhichisequippedwithliquid(suchasU-
Fig.1
- 7 -