CookTek MagnaWave MC2500 Руководство пользователя Установка и эксплуатация - Страница 10

Просмотреть онлайн или скачать pdf Руководство пользователя Установка и эксплуатация для Варочная панель CookTek MagnaWave MC2500. CookTek MagnaWave MC2500 11 страниц. Cooktek magnawave cooktops
Также для CookTek MagnaWave MC2500: Руководство пользователя (10 страниц), Руководство по установке и эксплуатации (10 страниц), Руководство пользователя и инструкции по установке (6 страниц)

In the event of a Possible Malfunction, your CookTek MagnaWave Cooktop
will display an Error Code on the LED Display. Please consult the following
table when encountering an Error Code.
Error Error Description
Code
1
RTD (temperature
sensor) is malfunctioning
2
RTD (temperature
sensor) temperature is
too high
3
Current is too high
4
Electronics are
overheating
6
Input Line (From Power
Outlet) Voltage Too High
7
Hardware failure
8
Zero cross error
16
System error
Two Hob (Two Position) Cooktops
Operation of the two hob (two position) Cooktop is exactly the same as the single
position Cooktop. Each position will have its own, independently controlled, On-
Off Control Knob and its own, separately controlled, SmarTemp button. It is not
necessary to turn on both positions for the Cooktop to function.
NOTE: For Proper operation a dedicated circuit should be used for each unit
installed. Each unit should be protected with a 30A minimum circuit breaker.
8
Potential Cause
RTD sensor has shorted
Glass surface is too hot or RTD
sensor has broken
Possible mechanical damage to
coil or foreign object on cooktop. may be required
Fan broken, bad ventilation,
ambient temperature too hot
Something else is one the same
circuit. Line voltage fluctuations
at end or beginning of work day.
(Voltage > 132Vac for 120V
model or > 264Vac for 240V
model)
Inverter I/O problem
Bad AC source, board
component failure
CPU I/O problem
Action Required
Reconnect or replace RTD.
Service may be required.
Remove any pans from cooktop
surface and let unit cool. Then
turn unit off, then on. If problem
was temperature related, the unit
will return to normal operation,
otherwise service is required.
Try different cookware. Service
Check airflow. Clear air vents.
Listen for fan operation.
To reset, unplug unit, wait
5 seconds, and plug in again.
If problem persists, have an
electrician monitor the line
voltage.
To reset, unplug unit, wait
5 seconds, and plug in again.
Service may be required.
Turn unit off, then on. Plug unit
into outlet on different circuit
breaker. If problem persists,
service is required on device.
To reset, unplug unit, wait
5 seconds, and plug in again.