CookTek SAS082-11 Руководство пользователя - Страница 13
Просмотреть онлайн или скачать pdf Руководство пользователя для Подогреватель продуктов CookTek SAS082-11. CookTek SAS082-11 16 страниц.
Maintenance
Follow the steps below when cleaning your SinAqua™
Souper™. Failure to adhere to these procedures may
damage components, resulting in a non-warranty
service call.
Step 1: Turn the Unit Off and Allow it to Cool
• Turn off the unit by touching the power button.
• If there is food in the tureen, remove and store it
as required.
Step 2: Clean the SinAqua
• With a clean, damp cloth, wipe the top and all
sides of the Souper™. A mild soap may be used.
DO NOT immerse the Souper™
it in the
dishwasher.
Troubleshooting
In the event of a possible malfunction, your CookTek Souper™ will beep and display an error code on the
alphanumeric display. Please consult the following table when encountering an error code. To reset error
conditions, press the POWER icon, or unplug the unit.
If any of the below errors persist after attempting the recommended "resolution," call 1-800-908-8726.
Code error Cause
1
Broken bottom temperature sensor
2
Broken heatsink temperature sensor
3
Input line current (instantaneous
rms) >20A
6
High line voltage (>264V)
7
Low line voltage (<85V)
8
Zero cross frequency out of range
(30-80Hz)
13
Dry tureen
16
Communication error
™
™
Souper
in water or place
Code
E--1
E--2
E--3
E--6
E--7
E--8
E--13
E--16
DO NOT pour water into the chamber that is
intended for the tureen. Water will drain (see
Figure 5, page 4).
DO NOT use steel wool or abrasive cleaners.
CAUTION: DO NOT splash or pour water
onto the charger's control panel or into the
intake/outlet vents. A possible shock hazard
may result and the unit may be damaged.
Step 3: Clean the Tureen
• Remove any product in the soup tureen.
• Wash the tureen in the sink using a mild soap and
water. The tureen is dishwasher safe.
DO NOT use abrasive cleaners on the tureen.
resolution
Service required.
Service required.
Remove power from the unit and allow it to cool
completely. Replace the tureen.
May result from power grid fluctuation and should
disappear once voltage returns to the normal level.
May result from power grid fluctuation and should
disappear once voltage returns to the normal level.
Turn unit off, then on. Plug unit into outlet on
different circuit breaker.
Remove the dry tureen or press the POWER icon.
Reset power by pressing the POWER icon.
7