austriamicrosystems AS5145A Руководство по эксплуатации - Страница 5

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Материнская плата austriamicrosystems AS5145A. austriamicrosystems AS5145A 12 страниц. Demoboard

4.3

The SSI tab

By selecting the SSI (serial protocol for AS5040, AS5140, AS5043, AS5143, AS5045, AS5145A/B) tab, the real time
information of the angular position and the status bits are displayed. See figure 4.
Magnet angle value
0 to 359.9°
Value is the Angle data [D11:D0] from the RD_ANGLE (Read Angle) serial command. This value is continuously
updated.
The Zero Pos. value represents the Zero Position register. By clicking on the Set button, the actual angle
"Value" is written into the Zero Position register. Clicking on Reset writes the value 0 to the Zero Position register.
The Magnetic Range Warning is continuously read from the RD_ANGLE serial command.
Green lamp: Magnet in range
Orange lamp: Magnet too far or too close. MagINC and MagDEC are set.
Red lamp: Magnet too far or too close, angle value is invalid and LIN bit is set.
The red lamp is available only when OTP MagCompEN=1, available from the OTP tab.
The Status bits information is taken from the serial stream.
The Read Interval can be modified from 10 ms (fastest) to 1 s (slowest).
Revision 1.3, 22-Jul-2009
Display update rate.
The readout speed can be adjusted
from 10ms to 1s
Figure 5: SSI tab, shows the SSI bus data of the selected encoder
www.austriamicrosystems.com
Not used
(dual die encoders only)
Angle value:
12 bit absolute position: 0 to 4095
Status bits information
Magnet range warning:
- Green: magnet in Range
- Orange: magnet too close or too far
- Red: magnet to close or too far, data
invalid (if MagCompEN = 1 only)
Set counter clockwise
Angle register value:
Zero position register access:
- Button SET: Sets the current angle
as the 0° angle
- Button RESET: resets the Zero
Position register to 0 (default)
Page 5 of 12