Setting the Decimal Point
The decimal point is normally set at a default place between the second and third digits on the
display. This can be changed to allow for a longer or shorter dispense time. To change the
decimal place position, press the SET button then the ◄ button 4 times. This will make the
decimal point blink. When the decimal point is blinking, you can then press the ▲ or ▼
buttons to adjust its position.
Auto-Purge Function
The auto-purge function is used when a material is being dispensed that may cure in the
dispensing needle if left sitting for long periods of time. Before auto purging your material, be
sure to read over the material SDS for any precautions that may need to be taken. Also be sure
that you have a proper storage container for the purged material.
In order to setup auto-purge on the SD-100 dispenser, the user must configure both the time it
needs to dispense (dispense time) and the time it pauses before dispensing again (wait time).
The total time will be the time it takes the dispenser to complete the whole cycle.
For example, let's say you wanted to auto-purge one second worth of material every five
seconds for a total time of six seconds. What you need to do is:
» Set the dispense time to 1 second.
» Set the wait time to 5 seconds.
Cycle Time = Dispense Time + Wait Time
SD-100 Digital Syringe Dispenser User Guide
15