HHO Plus CCPWM60A Руководство по установке - Страница 6

Просмотреть онлайн или скачать pdf Руководство по установке для Автомобильные аксессуары HHO Plus CCPWM60A. HHO Plus CCPWM60A 12 страниц. Hho hydrogen on demand dual fuel generator systems
Также для HHO Plus CCPWM60A: Руководство по установке (11 страниц), Руководство по установке (10 страниц), Руководство по установке (10 страниц)

HHO Plus CCPWM60A Руководство по установке

Electrical Connections

1. Make sure your engine is not running during installation;
2. Mount the product as near of the battery as possible (maximum 3 meters), providing that it is well
fixed. Please do not mount it over the battery.
3. Connect the "black" cable to the negative terminal of the battery.
4. Connect the "red" cable to the positive terminal of the battery.
5. Connect the "blue" cable to the negative cable coming from the HHO Cell.
6. Only use 6 mm section cable in your installation. Use the Yellow Female spade Connectors and plug the
cables in the male pins according to the previous picture.
Please refer to the illustrations below for typical configuration of the electrical connections of the CCPWM60A:
Red
HHO Plus, Alternative Energies, Lta – Travessa das Serras 33, Vieira de Leiria, Portugal – Tel. 00351244697116 – Email: [email protected]
Black
Blue
CCPWM60A – Installation Manual
Water Level Cables
6