Gage Bilt GB714 Оригинальное руководство по эксплуатации - Страница 14

Просмотреть онлайн или скачать pdf Оригинальное руководство по эксплуатации для Электроинструмент Gage Bilt GB714. Gage Bilt GB714 20 страниц.

Gage Bilt GB714 Оригинальное руководство по эксплуатации
WARNING:
Disconnect tool from its power source before actuator removal or installation. Severe personal injury may occur if
power source is not disconnected.
CAUTION:
Actuator assy-air (704130) can break if not careful.
CAUTION:
Do not over tighten actuator assy-air (704130). Snug tighten only.
REMOVING 704130 ACTUATOR ASSY-AIR
1.
Remove pin-slotted (400608) and actuator lever assy (704343) from handle assy (744129).
2.
Insert a 5/8" open end wrench around actuator assy-air (704130).
3.
Loosen the actuator assy-air (704130).
4.
Remove wrench. Unthread and remove the actuator assy-air (704130) with fingers from the
handle assy (744129).
INSTALLING 704130 ACTUATOR ASSY-AIR
1.
Apply Teflon® tape onto threads of actuator assy-air (704130) one to two wraps.
2.
Thread the actuator assy-air (704130) all the way into handle assy (744129) with fingers.
3.
Insert and turn 5/8" wrench and snug tight approximately 1/4-1/2 turn.
4.
Reattach pin-slotted (400608) and actuator lever assy (704343) to handle assy (744129).
.
GB714 INSTALLATION TOOL
S/N: 1001 AND ABOVE
PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.
OVERHAUL
ACTUATOR ASSY-AIR
14
REV. 3/21