Hi-Force HPP Series Руководство по эксплуатации - Страница 5

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Водяной насос Hi-Force HPP Series. Hi-Force HPP Series 16 страниц. Petrol driven hydraulic pumps

2.4 Hydraulic Pump Specific Safety Precautions

NEVER invert the pump or lay it on its side, either in use, in transport or in storage.
DO NOT weld any items to the pump or modify it in any way from its delivered condition. Your
warranty may be invalidated, and it could lead to serious personal injury.
NEVER exceed the maximum rated capacity of any hydraulic cylinder/tool. Hi-Force manufactures
its hydraulic pumps to operate at a maximum working pressure of 700 BAR (10,000 PSI). DO NOT
connect a cylinder/tool with a lower pressure capacity rating to any Hi-Force pump of this model
series.
This pump is not suitable for work which takes place in explosive environments.
ALWAYS stand the pump on a stable level surface during operation.
To protect your warranty, only use the hydraulic oil grade as specified in Section 5.4
Beware of hot surfaces on the engine.
Engine exhaust fumes are poisonous. Do not use the pump indoors.
Stop the engine when carrying out maintenance or adjustments (except pressure relief valve
adjustments). For details on engine operation refer to engine manufacturers instructions.
Hi-Force declares that this product has been tested and complies with the standards set out in the relevant
EU directives. The EU Declaration of Incorporation / Conformity is included as Annex A to this instruction
document and is supplied with all shipments of this product.
Failure to observe and obey the following safety precautions could result
in property damage, serious personal injury or death;
Failure to observe and obey the following safety precautions could result
in property damage, equipment damage or minor/moderate personal injury.

3.0 Declaration of Incorporation / Conformity

Operating Instruction Manual:
OM-HPP-01
5
From Serial Number:
ALL