Great Lakes Biostar V Руководство по эксплуатации - Страница 10

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Стоматологическое оборудование Great Lakes Biostar V. Great Lakes Biostar V 16 страниц.

Enough pellets must be placed in pellet cup to
hold the model at proper level. Material
termination areas, located on the facial surface of
the model, should be referenced at the same
height as the top ledge of the pellet cup.
Models attached to articulator mountings may be
referenced slightly higher than indicated.
Remove the pellet drawer and pour pellets
between the model and the inner wall of the cup.
Apply more than enough pellets in these areas.
Use a Biostar brush to remove excess pellets and
level the pellet line from the occlusal-incisal
plane to the top rim of the cup. Hold the brush at
an angle to sweep excess pellets from the rim of
the cup and the palatal area of the model.
Note: The pellet level should always be to the top
of the cup. The height of the model in the pellets
will change with various applications.
9