Dynabrade 10170 Краткое руководство по эксплуатации - Страница 4
Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Сандер Dynabrade 10170. Dynabrade 10170 4 страницы. Orbital sander
To Disassemble:
1. Disconnect tool from power source. Invert machine and secure in vise, using 57092 Collar (supplied in 57098 Repair Kit) or padded jaws.
2. Remove 56028 Muffler Cap and 56027 Muffler Insert (3) from 57066 Muffler Body. Using a 12mm hex wrench (supplied in 57098 Repair Kit), remove
muffler body and 57065 Cone Muffler from housing (not applicable for Self-Generated Vac to Central Vac).
Non-Vac to Self-Generated Vac for Hook-Up to Self-Contained Dust Collection System
1. Attach 57083 Vacuum Adapter to 57832 Vacuum Tube. Then attach to the housing making sure the tube is secured in the hole in the pad top.
2. Place 95526 O-Ring on the muffler body between the shoulder and the four (4) protrusions. Using a 12mm hex wrench, attach the muffler body, cone
muffler and O-ring to the housing through the vacuum adapter.
3. Place vacuum nozzle into the vacuum adapter with the slots facing outward making sure that the knob on the nozzle is aligned with the slot in the adapter.
4. Place 57067 Vacuum Tube into the vacuum adapter with the grooves facing inward until the adapter "snaps" onto the tube and the tube cannot be pulled
out. If the tube can be pulled out, rotate it 1/4 turn and place it back into the adapter until it "snaps".
5. Rotate tube until holes line up. Insert 96197 Dowel Pin in holes until it is centered.
6. Attach machine to portable dust collection system.
Non-Vac to Central Vac
1. Attach 57093 Vacuum Adapter to 57832 Vacuum Tube. Then attach to the housing making sure the tube is secured in the hole in the pad top.
2. Using a 12mm hex wrench, attach the muffler body and cone muffler to the housing through the central vacuum adapter.
3. Place muffler cap with inserts on muffler body making sure that the protrusions on the body fit in the pockets on the cap.
4. Attach machine to central vacuum system.
Self-Generated Vac to Central Vac
1. Remove 96197 Dowel Pin with an 1/8" drive pin.
2. Remove 57067 Vacuum Tube from the 57083 Vacuum Adapter by turning it clockwise while pulling backwards.
3. Using a small flat screwdriver, pry the vacuum nozzle until it is loose and then remove it by using two fingers to push and pull it until it hits the "legs" on the
vacuum adapter. Place the vacuum tube back into the vacuum adapter far enough to push the "legs" back then push the vacuum nozzle and the vacuum
tube out the rest of the way.
4. Using a 12mm hex wrench (supplied in 57098 Repair Kit), remove the 57066 Muffler Body, 57065 Cone Muffler and 95526 O-Ring from the housing
through the adapter. Remove the O-ring from the muffler body.
5. Remove 57083 Vacuum Adapter and attach 57093 Vacuum Adapter to to 57832 Vacuum Tube.
6. Using a 12mm hex wrench, attach the muffler body, cone muffler and O-ring to the housing through the central vacuum adapter.
7. Place muffler cap with inserts on muffler body making sure that the protrusions on the body fit in the pockets on the cap.
8. Attach machine to central vacuum system.
Central Vac to Self Generated Vac
1. Remove 57093 Central Vacuum Adapter and put the 57083 Vacuum Adapter in its place.
2. Place 95526 "O" Ring on the muffler body between the shoulder and the four (4) protrusions. Using a 12mm hex wrench (supplied in 57098 Repair Kit),
attach the muffler body, cone muffler and O-ring to the housing through the vacuum adapter.
3. Place vacuum nozzle into the vacuum adapter with the slots facing outward making sure that the knob on the nozzle is aligned with the slot in the adapter.
4. Place 57067 Vacuum Tube into the vacuum adapter with the grooves facing inward until the adapter "snaps" onto the tube and the tube cannot be pulled
out. If the tube can be pulled out, rotate it 1/4 turn and place it back into the adapter until it "snaps".
5. Rotate tube until holes line up. Insert 96197 Dowel Pin in holes until it is centered.
6. Attach machine to portable dust collection system.
96024 Motor Tune-Up Kit:
Includes assorted parts to help
maintain motor in tip-top shape.
Visit our new Web Site via Industry.Net MROP On-Line: http://www.dynabrade.industry.net
DYNABRADE, INC., 8989 Sheridan Drive • Clarence, NY 14031-1490 • Phone: (716) 631-0100 • Fax: 716-631-2073 • International Fax: 716-631-2524
DYNABRADE EUROPE S.àr.l.,
© DYNABRADE, INC., 1997
Vacuum Conversion Instructions
Accessories
Zone Artisanale • L-5485 Wormeldange—Haut, Luxembourg • Telephone: 352 76 84 94 • Fax: 352 76 84 95
57098 Motor Repair Kit:
Includes special tools for proper
disassembly/assembly of the machine.
E-Mail: [email protected]
®
DYNABRADE
PRINTED IN USA