Hi-Link HLK-LD2420 Руководство пользователя - Страница 9

Просмотреть онлайн или скачать pdf Руководство пользователя для Блок управления Hi-Link HLK-LD2420. Hi-Link HLK-LD2420 17 страниц.
Также для Hi-Link HLK-LD2420: Руководство пользователя (16 страниц)

HLK-LD2420
See Table 4-2 for the explanation of the parameters involved in the host computer tool interface.
parameter name
Used to set the minimum range gate for radar detection.
shortest distance
The resolution of the range gate is 70 cm.
Used to set the maximum range gate for radar detection.
maximum distance
The resolution of the range gate is 70 cm.
It takes a period of time T to switch the target state from occupied to unattended: during this
period, if a person is detected, the timing of this period of time will be restarted. The radar will switch
target disappears
delay
to the unmanned state and report unmanned only after detecting that the unmanned state lasts for
a complete T time.
It is used to set the sensitivity from unoccupied to occupied state. It is recommended to set it at more than 5
trigger threshold
times of the energy. For energy scanning and data viewing, please refer to4.2.2and4.2.3.
It is recommended to set the sensitivity at 2 to 5 times of the noise floor for detecting human micro-movement
hold threshold
and maintaining the human state. For energy scanning and data viewing, please refer to4.2.2and
4.2.3.

4.2.2.energy scan

The host computer energy scanning page is shown in Figure 4-3, and the energy scanning through the host computer is divided into three steps: .
step one,Set the scan interval and scan duration.
Step two,Set the data file save path.
Step three,Click "Start Scan".
The energy data will be stored in the set file path in the form of a folder, and a time stamp is added to the suffix of the folder name for distinction.
Keep the scan area clear of people during the energy scan.
Table 4-2 Explanation of the parameters of the upper computer tool interface
explain
7total pages15Page
user manual
parameter range
0~15
0~15
(not less than the minimum distance)
0~65535
0~65535
0~65535