Dynabrade 52689 Безопасность, эксплуатация и техническое обслуживание - Страница 2

Просмотреть онлайн или скачать pdf Безопасность, эксплуатация и техническое обслуживание для Шлифовальный станок Dynabrade 52689. Dynabrade 52689 9 страниц.

Dynabrade 52689 Безопасность, эксплуатация и техническое обслуживание
• Keep hand and clothing away from working end of the air tool.
Operation: Be sure that any loose clothing, hair and all jewelry is properly restrained.
• Secure inlet bushing on air tool with a wrench before attempting to install the air fitting to avoid damaging housing assembly.
• Check tool RPM (speed) with tachometer with air pressure set at 90 PSIG while the tool is running. If tool is operating at a higher speed than the RPM marked on the tool
housing, or operating improperly, the tool must be serviced and corrected before use.
Caution: Tool RPM must never exceed abrasive/accessory RPM rating. Check accessory manufacturer for details on maximum operating speed or special
mounting instructions.
• With power source disconnected from air tool, mount recommended accessory into collet assembly.
• The mandrel diameter of the abrasive/accessory must insert freely, but not loosely, all the way to the base of the collet body before tightening the collet cap. Use
wrenches provided.
Caution: The mandrel shall be inserted to the full depth of the gripping jaws of the collet. At least one-half the mandrel length shall be inserted into the collet to prevent
excessive overhang. Refer to accessory manufacturer's instructions for proper overhang. (Ref. ANSI B186.1)
Warning: Sliding the accessory's mandrel out from the collet insert creates an "OVER HANG" condition. This practice is NOT recommended, reducing the free speed of the tool
by reducing the air pressure must be done to avoid cutting tool breakage and serious injury.
MANDREL MOUNTING
• Connect air tool to power source. Be careful NOT to depress throttle lever in the process. Do not expose air tool to inlet pressure above 90 PSIG or (6.2 Bars).
Caution: After installing the accessory, before testing or use and/or after assembling tool, the grinder must be started at a reduced speed to check for good balance.
Gradually increase tool speed. DO NOT USE if tool vibration is excessive. Correct cause, and retest to insure safe operation.
• Make sure that work area is uncluttered, and visitors are at a safe range from the tools and debris.
• Use a vise or clamping device to hold work piece firmly in place.
• Do not apply excessive force on tool or apply "rough" treatment to it.
• Always work with a firm footing, posture and proper lighting.
Report to your supervisor any condition of the tool, accessories, or operation you consider unsafe.
Regulator
Filter
• Dynabrade Air Power Tools are designed to
operate at 90 PSIG (6.2 Bar/620 kPa) maximum
air pressure at the tool inlet, when the tool is
running. Use recommended regulator to control
air pressure.
• Ideally the air supply should be free from moisture.
Incorporating a refrigerated air dryer after the
compressor and drain valves at each tool station
(as shown) further reduces moisture from
condensation in the air supply.
OPERATING INSTRUCTIONS (continued)

Air System

Lubricator
90 PSIG
(6.2 Bar)
(Sloped in the direction of air flow)
To Tool Station
Drain
Valve
Collet Body
Collet Cap
Closed Loop Pipe System
Regulator
Filter
Lubricator
Ball
Valve
Drain
Air Hose
Valve
Coupler
Air Tool
90 PSIG MAX
(6.2 Bar)
Drain Valve
2
Correctly Mounted
Collet Insert
LUBRICATOR SETTING
1 DROP/MIN.
20 SCFM
Air Flow
Refrigerated
Air Dryer
Ball
Valve
Air Flow
Air Compressor
and Receiver