cessor the PS4 power mode. Pull PWREN to ground by placing a shorting jumper on J4 to enter DPSLP-
mode. This turns off outputs BUCK1, BUCK3, and EXT_EN.
BUCK3 Output Voltage Select: Select BUCK3=1.2V by leaving nIRQ, GPIO3, high. Select BUCK3=1.8V by
shorting nIRQ to ground.
DVS: BUCK2 is 0.9V in normal operation and 0.75V in DVS mode. Pull EXT_PG, GPIO4 to ground to enable
DVS mode.
Test Results
Innovative Power
TM
TM
ActiveSwitcher
is a trademark of Active-Semi.
5