DYNACO DY 4000 Руководство по электротехнике - Страница 12

Просмотреть онлайн или скачать pdf Руководство по электротехнике для Панель управления DYNACO DY 4000. DYNACO DY 4000 12 страниц.

DYNACO DY 4000 Руководство по электротехнике
Inputs
DYNACO USA, INC,
Input 7: Typically used for the open button on a three position switch.
Input will strictly open the door when activated.
Input 8: Typically used for the close button on a three position switch.
Input will strictly close the door when activated.
Input 9: Used for emergency stop or to stop door from being activated. Also
can be wired as the stop button in a three position switch.
Input 10: Used by DYNACO USA Inc. for optional operations ordered with
Dynaco door.
1
1
1
1
1
Remote E-stop
N/C Contact
Pull cord / push button
Motion sensor / Loop
Open
N/O Contact
Close
N/O Contact
Stop
N/C Contact
Figure 5.0-2: Basic Input Wiring
9
X2
X2
2
2
3
(Jumper)
N/O contact
N/O Contact
Reversing Edge
N/O Contact
The Leader in Door Safety & Design
11
4
7
8
9