Shock/Door/Window Contact | Installation Instructions
Calibrating Magnet Detection
When magnetic detection is first enabled, the RED LED will
blink to indicate that it is not calibrated. THE SENSOR MAGNET
CALIBRATION MUST BE COMPLETED TO OPERATE PROPERLY.
IF NOT CALIBRATED THE SENSOR WILL NOT TRANSMIT OPEN/
CLOSE INFORMATION TO THE CONTROL PANEL.
To calibrate the sensor:
1
Mount the sensor and magnet in it's final location as instructed
earlier in this document.
2
Close the door or window.
3
Press the Program button.
4
LED will start blinking ORANGE.
5
Open the door or window completely.
6
Press the Program button again.
7
LED will start blinking green
8
Fully close door or window and press the Program Button within
10 seconds to complete the calibration process..
9
LED will illuminate green for 2 seconds and then turn off and the
calibration is complete.
NOTE: If Magnet Detection is turned off then back on or if the battery
is removed or replaced, the sensor will lose the Magnet Calibration
setting and will have to be re-calibrated.
Installer Test Mode
To enter Installer Test Mode, remove the top housing from the sensor.
In this mode the LED will blink to indicate specific conditions.
Event
LED Color
Shock Detected
Red
Magnetic Detection
Green
Magnetic Tamper
Orange
Magnetic Calibration Required Red
Finalizing the Installation
Figure 4. Replacing Sensor Cover
D
C
1 Tilt the cover to align tab C through slot D.
2 Close the cover down, and press down until tab A snaps into slot B.
Shock Detection System Test - Glass Mounted
Firmly tap the glass twice with a hard plastic object (screwdriver
handle) within 12 inches of the sensor. Verify that the shock event
was received by the panel. It may take up to 2 seconds for the panel
to receive the notification.
NOTE: Do not strike the surface hard enough to break the glass.
Duration
ON for 8 seconds
Single Blink
Single Blink
Double Blink
B
A
Inserting and Replacing the Batteries
To insert or replace the batteries:
1 Press in the Retaining Tab (A) and gently swing the top of the
sensor up and off the base.
2 Place a small non-metal object in the slot on the side of the sensor
(see Part C,D in Figure 2, Shock / Door / Window Contact and
Battery Compartment).
3 Carefully push the battery out through the Battery Access slot.
Figure 5. Remove/Replace Battery
A
IMPORTANT: Always dispose and/or recycle used batteries in
accordance with the hazardous waste recovery and recycling
regulations for your location. Your city, state, or country may also
require you to comply with additional handling, recycling, and disposal
requirements.
1 Insert the replacement battery in the compartment. The positive (+)
sign on the battery should be facing down and the negative (–) side
facing up.
2 The Green LED will illuminate for 2 seconds as the Device powers up.
3 Replace the top case (see Finalizing the Installation, above).
WARNING: Failure to follow these warnings and instructions can lead
to heat generation, rupture, leakage, explosion, fire, or other injury, or
damage. Do not insert the battery into the compartment in the wrong
direction. Always replace the battery with the same or equivalent type.
Never recharge or disassemble the battery. Never place the battery in
fire or water. Always keep batteries away from small children. If batter-
ies are swallowed, promptly see a doctor.
Restore Factory Settings
Press and hold the program button for more than 10 seconds:
● Release the program button after the Orange LED flashes three times.
● Press and release the program button once more to confirm that
factory defaults are to be restored. If this is not done within 5
seconds, the reset function will be terminated with no change to the
programmed settings.
The Red LED will flash as per the programmed shock sensor setting then
the Green LED will flash per the programmed Magnet Detection setting.
3