CEL-MAR ADA-1020 Руководство пользователя - Страница 9
Просмотреть онлайн или скачать pdf Руководство пользователя для Медиаконвертер CEL-MAR ADA-1020. CEL-MAR ADA-1020 12 страниц. Rs-232 to current loop converter

ADA-1020
Fig 10. Example connection of ADA-1020 converters as Current Loop bus for 15 SLAVE converters
3.5.2. 3.5.1. CONNECTION OF 5 RS232 INTERFACE DEVICES TO CURRENT LOOP BUS
In this case/example the Current Loop bus is created by one ADA-1020 converter (MASTER – active transmitter) and one ADA-1020
converter (SLAVE – active transmitter - the furthest located from the MASTER) and max. 4 converters ADA-1020 (SLAVE – passive
transmitter). Connection made via Rx+* receiver terminal increases the resistance of the current loop receiver of overvoltage arising
Current Loop bus.
The number of the SLAVE converters can be less for long lines. Example of connection is shown below.
ADA-1020-1-2-2-3
SLAVE-ACTIVE-15
DB-9F
Current Loop
RS232
Rx+
Tx (2)
Rx+*
Rx (3)
Rx-
.
Tx+
GND (5)
Tx-
ADA-1020-1-2-2-3
SLAVE-PASSIVE-2
DB-9F
Current Loop
RS232
Rx+
Tx (2)
Rx+*
Rx (3)
Rx-
.
Tx+
GND (5)
Tx-
ADA-1020-1-2-2-3
SLAVE-PASSIVE-1
DB-9F
Current Loop
RS232
Rx+
Tx (2)
Rx+*
Rx (3)
Rx-
.
Tx+
GND (5)
Tx-
9
RS232
Rx
Tx
.
GND
RS232
Rx
Tx
.
GND
RS232
Rx
Tx
.
GND