Automate AM2 Руководство по установке - Страница 12
Просмотреть онлайн или скачать pdf Руководство по установке для Пульт дистанционного управления Automate AM2. Automate AM2 18 страниц.
Также для Automate AM2: Руководство пользователя (19 страниц)
1 A A C C T T I I V V E E /PASSIVE/AUTO REARM ARMING: When active arming is selected, the system will
only arm when the transmitter is used. When set to passive, the system will arm automatically 30
seconds after the ignition is turned off. When set to auto rearm, the system will not arm by itself
when the ignition is turned off but will rearm 30 seconds after being disarmed by the remote if the
ignition was never turned on indicating the vehicle was never entered.
2 H H O O R R N N H H O O N N K K ON/OFF/OEM: When horn honk is selected on, the system will honk the horn
upon lock and unlock. When off is selected, the system will not honk upon lock and unlock. When
OEM is selected, the horn will only honk upon pressing lock twice and not upon unlock.
3 HORN OUTPUT DURATION: This is the pulsed time output for the horn. On some vehicles
the horn output may respond differently than others, the default is 5 5 0 0 m m s s .
4 IGNITION LOCK: When selected O O F F F F , upon turning the ignition on the doors will not lock.
When selected ON, upon turning the ignition on the doors will lock.
5 IGNITION UNLOCK: When selected O O F F F F , upon turning the ignition off the doors will not
unlock. When selected ON, upon turning the ignition off the doors will unlock.
6 A A C C T T I I V V E E /PASSIVE LOCKING: When active locking is selected, the doors will only lock via the
remote. If passive arming or auto rearm is selected from feature 1, you can choose passive locking
to have the locks automatically lock upon the system arming itself.
7 IGNITION-CONTROLLED DOMELIGHT: When selected O O N N , the system will turn on the
domelight for 30 seconds when the ignition is turned off, and also turn on upon unlock/disarm.
When the feature is selected OFF, the domelight output will turn on the domelight for 30 seconds
upon unlocking only.
8 DOOR LOCK PULSE DURATION: Some European vehicles, such as Mercedes-Benz and Audi,
require longer lock and unlock pulses to operate the vacuum pump. Programming the system to
provide 3.5 second pulses, will accommodate the door lock interface in these vehicles. Vehicles with
factory comfort closure it may be necessary to shorten the pulse to 0.4 seconds. Upon locking or
unlocking the doors the windows may vent or roll down in those cases. The default setting is 0 0 . . 8 8
second door lock pulses.
9 DOUBLE PULSE UNLOCK: Defaulted O O F F F F , but when selecting on it will program the unlock
output from one to two pulses.
10 DOUBLE PULSE LOCK: Defaulted O O F F F F , but when selected on it will program the lock output
from one to two pulses.
12
©
2007
.
Directed Electronics