(11) After the diaphragm mounting blocks have been installed, fix the new casing blocks by tightening
the four screws evenly in the reverse order to that done for disassembling, fit the L-tube in the
casing nozzle, and fix it firmly using the hose band. (Figs.21 and 22).
Fig. 21
Screw
(12) When all the reassembly work has been completed, check the rod for no contact with the
electromagnet(s) or the screws for tightness.
(13) As a final step, put the frame cover back on the frame, tighten the four screws uniformly, then
cover the frame with the sound absorber. Furthermore, do not forget to put the frame cover on,
tighten each of four screws gradually and uniformly until they are firmly fastened.
• Tightening a single screw too tight will make it difficult to tighten the remaining screws firmly, result-
ingin damage to the screws if forcibly tightened. Therefore, fasten all the four screws uniformly.
Fig. 23
12
Fig. 22
CAUTION
Fig. 24
Sound absorber
Hose band
(Figs. 23 and 24)
Screw