(1) Prior to starting the work, be sure to unplug the pump.
(2) Remove all screws from the four corners, and the upper housing. If it is difficult to remove it due
tothe heavily stuck internal seal packing, pry it open by inserting the tip of a screwdriver into the
clearance between the exhaust nozzle and the upper housing .
Fig. 3
Screwdriver
inserting
position
(3) Remove the sound absorber, hold the hose band and remove the L-tube from the casing nozzle.
Then, loosen the installation screws of the casing block for removal of the latter. (Figs. 5 and 6)
Fig. 5
Screw
Sound absorber
Fig. 4
Upper housing
Fig. 6
Hose band
L-tube
Screw
(Figs. 3 and 4)
Sound absorber
Casing Block