Decommissioning
Temporary decommissioning
For a temporary shutdown of the minimum quantity lubrication system, disconnect the entire
system from the compressed air and electrical power supply and depressurize the tank. In the
case of a longer shutdown, it is advisable to also drain the lubricant.
Final decommissioning
If you want to permanently shut down the minimum quantity lubrication system, please
observe the legal regulations for the disposal of oil-bearing components.
Technical specifications
Description
Reservoir
Housing design
Mounting position
Capacity
Coolant consumption
Coolant outlets
Mass
Compressed air
Input pressure max.
Input pressure min.
Operating pressure max.
Air consumption
Connections
Compressed air connection
Unit
DYNACUT MDM
PE-plastic
Vertical
l
1,5
ml/h
0-100
1-2
kg
3
Bar
8
Bar
2,5
Bar
2 (Adjusted to 1,0 bar)
l/min
25-50 Per exit
mm
6