GAI-Tronics 354-700RD Руководство - Страница 3

Просмотреть онлайн или скачать pdf Руководство для Телефон GAI-Tronics 354-700RD. GAI-Tronics 354-700RD 17 страниц. 354-70x series nema 4x voip telephone

GAI-Tronics 354-700RD Руководство
NEMA 4X VoIP Telephones
Feature and Functions
GAI-Tronics VoIP telephones include the following features:
NEMA 4X rated with door closed (NEMA 3R with door open)
Handset with 6-foot Hytrel coiled cord and noise-cancelling microphone
Panel-mounted push-button volume control
Chrome-plated keypad with protective rubber boot and braille reference
Brushed stainless steel panel
Stainless steel assembly hardware.
SIP compatible (RFC3261)
Real-time alarm reporting via email or syslog
Power-over-Ethernet compatible (Power Mode A, Class 0)
Configurable via web page, serial link or download
Four configurable auxiliary inputs and two configurable voltage-free contact outputs

Installation Guidelines

ATTENTION
accordance with the National Electrical Code or applicable local codes.
When installing any GAI-Tronics telephone equipment, please adhere to the following guidelines to
ensure the safety of all personnel:
NEVER install telephone wiring during a lightning storm.
Install a UL Listed lightning arrestor on any telephone installed where the telephone or telephone
cable is at risk of being exposed to lightning strikes. The lightning arrestor must be installed as close
to the telephone as possible to maximize the protection. The lightning arrestor must not be installed
within the enclosure supplied with the telephone.
NEVER install telephone jacks in wet locations unless the jack is specifically designed for wet
locations.
NEVER touch uninsulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
USE CAUTION when installing or modifying telephone lines.
Install a UL Listed telephone line suppressor (customer-supplied) on the telephone line.
Use silicone sealant or equivalent around and inside of all conduit entries
Install a Cat5 data line lightning surge protector on any phone installed where the phone or phone
cable is at risk of being exposed to lightning strikes. The lightning arrestor must be installed as close
to the phone as possible in a non-hazardous environment. The lightning arrestor must not be installed
within the telephone enclosure.
USE CAUTION when installing or modifying Category 5 data lines.
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-520A.docx
03/17
Installation should be performed by qualified personnel and only in
Pub. 42004-520A
Page 3 of 15