GAI-Tronics 354-700YL Руководство - Страница 5

Просмотреть онлайн или скачать pdf Руководство для Телефон GAI-Tronics 354-700YL. GAI-Tronics 354-700YL 17 страниц. 354-70x series nema 4x voip telephone

GAI-Tronics 354-700YL Руководство
Pub. 42004-520A
NEMA 4X VoIP Telephones
Page 5 of 15
Mounting the Enclosure
Mount the enclosure using the four 0.437-inch (11mm) diameter holes located on the mounting flanges
with 3/8-inch (M8) hardware. The recommended entry is via the enclosure bottom to prevent moisture
from dripping onto the connection terminals. When mounting the enclosure, use caution to avoid
damaging the internal components. The suggested mounting height is 48 inches (1219 mm) to the center
of the bottom mounting holes of the enclosure.
Figure 2. Mounting and Entry Locations
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-520A.docx