3.1.2-) Internal Signal Mode:
The amplifier can generate sine signal from 1 Hz to 15 kHz with 1 Hz
increments that the user can adjust with the Sine Frequency Generator
Switch. Connect DC power source and drive signal to shaker power input.
Pull the Gain Knob out.
Raise or lower the Sine Frequency Generator Switch to the desired Sine
frequency. Adjust the Gain of the amplifier by turning the Gain Knob
clockwise. The frequency of the generated sine signal will be visible on the
LCD Screen.
9