SYMPTOM
DOOR WILL NOT LOCK
OR NO MAGNETIC
HOLDING FORCE
LOW HOLDING FORCE
MAGNET OVERHEATS
AND / OR DRAWS EXCESS
CURRENT
DYNASTAT BOND SENSOR
NOT INDICATING DOOR
SECURE WHEN CLOSED
AND LOCKED
(WHEN APPLICABLE)
DSM (DOOR STATUS
MONITOR) NOT
INDICATING DOOR
CLOSED / OPEN STATUS
(WHEN APPLICABLE)
TROUBLESHOOTING TIPS
POSSIBLE
CAUSE
NO INPUT POWER
REVERSED POLARITY
AN OPEN CIRCUIT
IN THE COIL
WRONG INPUT VOLTAGE
VOLTAGE SELECT JUMPERS
SET WRONG
ARMATURE MOUNTING
TOO RIGID
LOCK SET FOR 12V WITH
24V APPLIED
POSSIBLE SHORTED COIL
INSUFFICIENT SUPPLY VOLTAGE
MAGNET AND / OR ARMATURE
FACE DIRTY OR BURRED
POOR LOCK / ARMATURE
ALIGNMENT
DSM MAGNETS NOT INSTALLED
IN ARMATURE HOUSING
POOR LOCK / ARMATURE
ALIGNMENT
CHECK FOR
CHECK ALL CONNECTIONS.
CHECK FOR VOLTAGE AT POWER SOURCE
AND LOCK TERMINAL STRIP.
IF A LOCK IS OPERATING ON DC VOLTAGE
CHECK FOR REVERSED POLARITY.
REFER TO FIG
PERFORM THE COIL RESISTANCE CHECK.
REFER TO BOTTOM OF THE PAGE 3.
VERIFY INPUT VOLTAGE MATCHES JUMPER
SETTING. SEE TOP OF PAGE 2.
VERIFY THAT JUMPERS MATCH INPUT
VOLTAGE. SEE TOP OF PAGE 2.
CHECK ARMATURE MOUNTING FOR FREE
PIVOTING AND FULL CONTACT BETWEEN
THE MATING SURFACE OF THE LOCK
AND ARMATURE.
VERIFY THAT JUMPERS MATCH
INPUT VOLTAGE. SEE TOP OF PAGE 2.
PERFORM THE COIL RESISTANCE CHECK.
REFER TO BOTTOM OF PAGE 3.
CHECK SUPPLY FOR PROPER INPUT
VOLTAGE, SHOULD BE WITHIN 10%
CLEAN BOTH SURFACES WITH SCOTCH
BRITE TYPE CLOTH AND APPLY WD-40.
CHECK FOR BURRS.
CORRECT AS NECESSARY
REPLACE / INSTALL AS NECESSARY
CORRECT AS NECESSARY
4
"A"
PAGE 2.