AutomationDirect IRON HORSE GSD5-240-10N4-V Руководство пользователя - Страница 15
Просмотреть онлайн или скачать pdf Руководство пользователя для Приводы постоянного тока AutomationDirect IRON HORSE GSD5-240-10N4-V. AutomationDirect IRON HORSE GSD5-240-10N4-V 16 страниц.
GSD5 Series Accessories
GSDA-AI-V5
Optional analog voltage or current input card for open-frame GSD5-240-10C series DC drives only
This option card allows for the use of either a grounded or non-grounded remote DC signal such as
0–5 VDC through 0–250 VDC, 4–20mA, or a remote speed potentiometer. The DC input signal type can
be selected for voltage (V
(P4) selection that should be set to the (Lo) setting when using a 4–20mA signal or voltage ranges of
0–5 VDC through 0–25 VDC. When using voltage ranges of 0–25 VDC through 0–250 VDC, this jumper
must be set to (Hi). The GAIN trim pot is used to set full linear output in reference to the input signal
range. The output of this remote signal isolation board is a linear signal that is proportional to the
remote input signal being supplied.
GSDA-AI-V5 Mounting and Wiring Diagram
MIN
P1
JU2
ORANGE
JU3
JU1
GSD5-240-10C with
GSDA-AI-V5 installed
GSDA-AI-V5 Setup Procedure
1) With motor connected and NO power at the drive, connect a DC voltmeter (meter must not be
grounded) to control outputs as follows: Meter COMMON to the -ARM terminal; Meter POSITIVE
to the +ARM terminal Select correct meter range (0-90V or 0-180V)
2) Preset GAIN trim pot (analog voltage follower board) fully CCW, place range jumper clip in proper
position
3) Preset control as follows: MIN and IR COMP fully CCW; MAX at 50%
4) Apply desired AC voltage to drive and analog voltage follower board
5) With 0 volts into analog voltage follower board, adjust MIN trim pot on drive to eliminate
deadband To do this, increase MIN fully CW, and then adjust CCW until meter reads 0V
6) Apply maximum input voltage to analog voltage follower board input
7) Adjust GAIN until no further change in voltage output occurs, then turn CCW until a 5V drop
occurs, and then set control MAX to 90VDC (for 120V input) or 180VDC (for 240V input)
8) For Closed Loop systems the IR COMP should remain fully CCW For Open Loop systems, set IR
per set-up procedure
9) Some interaction between trimpots may occur Recheck the MIN trim pot setting and repeat steps 5
through 7 as needed
IronHorse GSD5 DC Drives User Manual – 1st Ed, Rev E – 05/13/2020
) or current (4–20mA) via the JP2 jumper clip. There is a Hi/Lo range jumper
in
MAX
ACCEL
IR COMP
Vin or 4-20mA
CONNECTOR
RANGE
JUMPER
GAIN
CONNECTOR
TRIMPOT
P3
-1
4-20
-2
-3
Vin
-1
-2
-3
P4
JP2
-ARM
+ARM
AC1
AC2
CUSTOMER
CUSTOMER
COMMON
SIGNAL
CUR LIM
The Kit Includes:
• (1) option card
• (3) spacers (025 x 05 in)
• (3) Phillips-head screws (#6-32 x 075
Spacers:
P2
Install spacers at JU1, JU3, and JU5, as
illustrated.
JU4
Wiring Jumpers:
Connect wires JU2 and JU4 as
JU5
illustrated.
in)
Page 15