8.5.-Residual hardness setting
Once the valve is in the service position, it's time to adjust
the residual hardness. Hidro-Water, S.L. (if there isn't any
other data to be considered) recommends leaving residual
hardness between 8 and 10 French degrees (°fH).
As in the programming we have programmed it to 90 ppm
= 9 ° fH, we should leave it at that measure.
Using the mixing valve located on the left side of the valve:
•
Turn it ½ way clockwise.
•
Let the water run for a minute to change the water in the pipes.
•
Take a sample of water and measure the hardness with a IN-0402-02 harness test kit.
•
Make slight adjustments to get it to the required 90 ppm.
Turning clockwise increases hardness.
On the contrary, if you turn anticlockwise, the hardness is reduced.
8.6.- Adding salt
Once you have started up the system, it's time to add the salt. Salt will be the regenerator
that the softener resins use to recover their exchange capacity and start their work cycle again.
To do so, Hidro-Water recommends using special refined and compact salt designed for water
treatment as it guarantees that it's free of impurities that could damage your system.
20
MA-EN-DESCALCIFICADOR KOBE (USR) UF-3004-XX JD18V01
Procedure:
1. Open the tank's lid.
2. Add the salt in the correct compartment
This type of salt usually comes in 25kg bags. The amount is irrelevant as long as you assure
that there's enough salt to exceed the water level and thus guaranteeing brine saturation.
The amount needed to regenerate depends on the model and is related to the last table on
system's technical data; point 2.7.- Characteristics in this manual. We advise you to add more
salt the recommended amount so you don't have to keep an eye on the system so often.
Even if you add more salt that the recommended amount, the system will only use
the amount it needs and will accumulate the rest for future regenerations
8.7.- Checking the flow meter
To check if the flow meter works and that the system will
L
carry out volumetric regenerations, press the
MIN
button until seeing the screen like the image.
After, open a faucet that depends on the system and
check how the flow is increased instantly.
If not, make sure that the flow meter's connector is well connected in its place.
If it is and still doesn't work, take apart the turbine and see if it spins freely and not being obstructed
by any foreign body. Put together again.