Hidrotermal Hidro-SP026 Руководство по установке и обслуживанию - Страница 11

Просмотреть онлайн или скачать pdf Руководство по установке и обслуживанию для Насос для плавательного бассейна Hidrotermal Hidro-SP026. Hidrotermal Hidro-SP026 11 страниц. Solar powered swimming pool pump

Hidrotermal Hidro-SP026 Руководство по установке и обслуживанию
uFault Information and Troubleshooting Method
Fault
NO
Code
1
P0
2
P43
3
P46
4
P49
5
P50
6
P51
7
P48
8
P60
9
E8
10
PL
11
ALARM
12
P42
Fault
Description
Hardware
Overcurrent
Phase
Protection
Stall
Protection
Software
Overcurrent
Low Voltage
Protection
High Voltage
Protection
Dry-run
Protection
High Temperature
Protection
Current Sampling
Failure
Power Shortage
Reverse connection
protect
Start fault
Cause and Solutions of Fault
★Motor model is mismatch, please choose
matching pumps.
★UVW three-phase short-circuit
connection, please rewiring to ensure the
normal installation of UVW.
UVW three-phase open circult, please
rewiring to ensure it reliable contact.
★Motor model is mismatch, please choose
matching pumps.
★Pump extension cord is too long. Please
reduce the extension cord.
★Power is too low, increase the power
supply.
★Pump bearing is stuck, please clean
pump bearings.
★Water pump bearing stuck, clean pump
bearings.
★UVW three-phase short-circuit
connection, please rewiring to ensure the
normal installation of UVW.
The input voltage is too low, please
distribute power refer to the electrical
characteristics.
The input voltage is too low, please
distribute power refer to the electrical
characteristics.
★Not all of air in the pump is exhausted,
cut off the power, re-power and start the
pump drainage after 30 seconds.
★There is no water in the water tank
waiting for water, it will restart.
The temperature of controller MCU is more
than 90℃.
Cut off the power and restart after 30
seconds.
★No sunlight, waiting for the sunllight to
restart.
★Solar panel matching error, refer to the
recommendation to match correctly.
Exchange the positive and negative wire.
1-7 fault, appear continuously for several
times in 10 minute. Check NO.1-7 fault.
10
Recovery
Procedure
Automatically
remove after 30s
Automatically
remove after 30s
Automatically
remove after 30s
Automatically
remove after 30s
Voltage return to
normal, remove the
fault immediately
Voltage return to
normal, remove the
fault immediately
Automatically clear
after 30 minutes or
re-power to clear
Automatically clear
after the temperature
is normal
Restart the power
At the first 5 times, it
will removal after 30
seconds, and then
30 minutes to
rempval
Restart the power
Restart power