CELETTE DUO SPOT Оригинальное руководство - Страница 16
Просмотреть онлайн или скачать pdf Оригинальное руководство для Сварочная система CELETTE DUO SPOT. CELETTE DUO SPOT 20 страниц.
4. TROUBLE SHOOTING:
The machine with three protection function. If the machine is abnormal, please refer to the following:
1. Over heat protection:
There is a aux transformer inside the machine. The aux transformer is with thermal switch. The
temperature of the transformer will rise following the machine work duty. If the machine is over duty and
over heat, the "auto" and "manual" indicator on front will light up, the machine will stop output. In general,
the machine duty cycle is enough to car body repair. If the machine over heat protection on low work
duty, please check the fan.
2. Short circuit protection:
After the machine output power, if the torch and earth cable are keeping short circuit, the machine will
stop charge. The torch and earth cable need to open circuit, the machine can charge and welding again.
3. Over current protection:
In current sample is without this function. But we plan to add fuse in future. If the fuse is broken, it
means the machine is abnormal and over current, please contact to the after service.
No power
No weld
Fan is not working
www.celette.com
1. Check the source power
2. Check the input cable
3. Check the main switch
4. Please contact to the manufacturer
1. Check the output cable for torch & earth
2. Check the connection for torch & earth
3. Check power fuse
4. Check transformer, maybe over heat
5. Please contact to the manufacturer
1. Check the power of fan
2. Check the fan, maybe something stuck in the fan
3. Please contact to the manufacturer
Page No: 16