13.Maintenance

※Before check-up please turn off the softener inlet valve or bypass valve to bypass position.
※Prohibited to use harmful detergents or chemicals to clean, wipe the device.
※Wipe with a moistened soft fabrics to clean equipment surface dust and foreign matter, aviod
the water into the valve internal erosion electrical components causing damage.
※Disassembly way (Before disassembly, the device should be under brine status that will make
it convenient for maintenance).
Softener
Uninstall Control
Valve
Note:
● When check or replace the resin, ensure the length of riser tube should be neither higher nor
lower 10mm tank top opening height(See picture 1), and its top end should be rounded to avoid
damage of O-ring inside the valve.
● Avoid floccules substance together with resin to fill in the mineral tank.
● Avoid the inside O-ring falling out while install the control valve on the tank.
Uninstall Brine
Uninstall Dustproof
Valve Riser Tube
Valve
A
A≤10mm
Remove Resin Tank
Riser Pipe
Resin Tank
13
Take Out Resin
Tank