TROUBLESHOOTING
SYMPTOM
SOLUTION
Fan will not start
Fan Sounds Noisy
Fan Wobble
Fans/Light Turn On
and Off Unexpectedly
Frequency
Interference
Check to make sure the wall switch is turned on.
Check circuit fuses or breakers.
Caution! Make sure the power is turned off before performing the following steps.
Remove canopy and check wire connections.
Check wall control transmitter connections (if applicable).
Note: Fan must be installed at a maximum distance of 40 feet from the transmitting unit
for proper signal transmission between the transmitting unit and the fan's receiving unit.
Allow a 24-hour "break in" period. Most noises associated with a new fan will go away
during this time.
Make sure the screws that attach the fan blade holder to the motor hub is tight.
Make sure outlet box is secured to building structure, if necessary use the wood screws
provided to further secure outlet box to joist.
Make sure hanger bracket is secure to the outlet box, screws are tight.
NOTE: All blade sets are grouped by weight. Because wood and plastic blades vary in
density, the fan may wobble even though blades are matched.
Make sure outlet box is secured to building structure, if necessary use the wood screws
provided to further secure outlet box to joist.
Make sure hanger bracket is secure to the outlet box, screws are tight.
If a Balancing kit is provided follow the instructions included with the balancing kit to
help correct any excessive wobble.
This is caused by interference, Please see "Frequency interference" for steps to change
the frequency.
Turn the power off to your ceiling fan.
Please use a small size tool to change the frequency settings on the control system.
Return power to the unit.
NOTE: After the AC power is on, do not press any other button on the transmitter before
pressing the"Stop" button, doing so will cause the procedure to fail.
Within 60 seconds of turning the Fan's AC power ON, Press the transmitter's "Stop" button
and hold the "Stop" button for 10 seconds.
Once the receiver has detected the set frequency, the down light of your fan if applicable
will blink twice. (There is no indication if your fan is not equipped with a light).
The receiver has now learn the frequency which has been selected on the transmitter. After
completing the steps above, you should be able to operate the ceiling fan and light. If the
fan is not responding to the transmitter, please turn the power off to the receiver, and
repeat the process.