INSTALLATION INSTRUCTIONS
SINGLE SPLIT WALL MOUNTED AIR CONDITIONER
• Please read this instruction sheet completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized
personnel only.
• Installation work must be performed in accordance with the national wiring standards by
authorized personnel only.
Installation Parts Provided
zzz
yyy
1. Type "A" screw
2. Installation Plate
|||
zzz
yyy
3. Type "B" screw
4. Holder Remote Control
|||
zzz
yyy
More than
5cm
(Left and right
are identical)
More than 70cm
• This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
More than
5cm
Air filter
Saddle
More than
60cm
More than
More than
10cm
10cm
Installation parts you
must purchase
Installation plate
Sleeve
Bushing-Sleeve
Putty(Gum Type Sealer)
Bend the pipe as closely
on the wall as possible,
but be careful that it
doesn't break.
Vinyl tape (Wide)
• Apply after carrying out a
drainage test.
• To carry out the drainage
test, remove the air filters
and pour water into the heat
exchanger.
Gas side piping
Liquid side piping
Additional drain pipe
Vinyl tape (Narrow)
Connecting cable: Cooling & Heat pump: 2EA
Cooling only: 1EA
P/No. : 3828AR7314S