Bundle the piping and drain hose together by
wrapping them with cloth tape over the range
within which they fit into the rear piping housing
section.
Drain hose
Reroute the pipings and the drain hose across
H
the back of the chassis.
Piping for
passage through
piping hole
Set the pipings and the drain hose to the back of
I
the chassis with the tubing holder.
Hook the edge of tubing holder to tap on chassis
and push the bottom of tubing holder to be
engaged at the bottom of chassis.
Tubing holder
Push
2
Indoor unit installation
J
Remove the spacer.
Ensure that the hooks are properly seated on the
installation plate by moving it left and right.
Press the lower left and right sides of the unit against
the installation plate until the hooks engage into their
slots(clicking sound).
Pipe
Vinyl tape(narrow)
Wrap with
vinyl tape(wide)
1
Hook
Connecting
cable
Drain hose
10
Connection of the
pipes-Outdoor
Align the center of the pipings and
A
sufficiently tighten the flare nut by hand.
Finally, tighten the flare nut with torque
B
wrench until the wrench clicks.
When tightening the flare nut with torque
wrench, ensure the direction for tightening
follows the arrow on the wrench.
Pipe Size[Torque]
Capacity
(Btu/h)
GAS
1/2"[5.5kg . m]
18K, 24K, 26K
5/8"[6.6kg . m]
Outdoor unit
Outdoor unit
Liquid side piping
(Smaller diameter)
Torque wrench
Torque wrench
LIQUID
1/4"[1.8kg . m]
3/8"[4.2kg . m]
Gas side
piping
(Bigger