Autonics BC15-LDT-C-P Руководство - Страница 4

Просмотреть онлайн или скачать pdf Руководство для Аксессуары Autonics BC15-LDT-C-P. Autonics BC15-LDT-C-P 7 страниц.

Autonics BC15-LDT-C-P Руководство
BC Series
Functions
Color teaching
Set the reference color with the teaching function. Press the SET key in RUN mode to enter teaching standby status. Place the desired
color at the sensing position (spot) and hold the SET key for over 3 seconds.
When teaching is complete, the teaching color indicator will turn ON.
When there is an error, the operation indicator will flash (red).
Display teaching
The set reference color can be displayed on the teaching indicator.
With the ability to check the set reference color there is no need to re-set the teaching color every time.
It may difficult to check the similar colors when installing multiple sensors.
Teaching indicator color is available only for reference.
※The teaching color and the color displayed on the teaching indicator may differ depending on environment conditions (ambient light,
reflection angle, material, etc.)
Sensing mode, sensitivity setting (color tolerance)
Two sensing modes; C (color only) mode discriminates by color rate and C+I (color +intensity) mode discriminates by color rate and contrast.
Set the sensing sensitivity (fine, normal, rough) at each sensing mode.
Color match/mismatch mode
- Color match mode (N.O.) : Output ON when target color matches reference color.
Turn the color match/mismatch switch towards N.O.
- Color mismatch mode (N.C.) : Output ON when target color does not match reference color.
Turn the color match/mismatch switch towards N.C.
OFF delay timer
Timer (40ms OFF delay) functions helps prevent output malfunction from target objects moving too rapidly. The timer indicator turns ON
(orange) when the timer function is set.

Operation and Settings

Start
teaching
Teaching standby
OUT
SET
※1
Start teaching
OUT
Normal
SET
Error
※ Indicator status
ON
Flashing (every 0.5 sec)
OFF
※Settings can be configured externally using SET cable.
※1: After teaching is complete, the unit will return to RUN mode
automatically.
When there is no SET input for 10 seconds during teaching standby,
the unit will return to RUN mode.
※2: Light color varies depending on error type. Please refer to
"
Indicator display".
A-12
11 4425-5103
SET
over 3 sec
Teaching
standby
RUN mode
SET
Teaching
Teaching
STB
indicator
(orange)
SET
over 3 sec
Teaching
STB
indicator
SET
over 1 sec
(teaching color)
※2
11 98782-2296 Internet: www.smartec-automacao.com.br
SET
SET
over 5 sec
RUN
mode
SET
SET
over 1 sec
SET
over 3 sec
Sensing mode,
sensitivity setting
SET
over 5 sec
Timer setting
Sensing mode, sensitivity setting
Timer ON
OUT
STB
TMR
SET
Timer OFF
OUT
STB
TMR
SET
over 1 sec
Timer setting
SET
over 3 sec
C mode: Fine
Teaching
OUT
STB
indicator
(red)
SET
C mode: Normal
Teaching
OUT
STB
indicator
(green)
SET
C mode: Rough
Teaching
OUT
STB
indicator
(blue)
SET
C+I mode: Fine
Teaching
OUT
STB
indicator
(red)
SET
C+I mode: Normal
Teaching
OUT
STB
indicator
(green)
SET
C+I mode: Rough
Teaching
OUT
STB
indicator
(blue)