22. Quick reference, the most important facts on a single sheet
Basic requirement: Controller PFS/PFC operating in frequency 434.075 MHz (i.e. radio channel 41)
Batteries: 2 pcs. alkaline 1.5 Volts, size AA
Switching on: Short activation of sensor field 'On', devices starts, receiving mode
Switching off: Short activation of sensor field 'On'
How to determine the battery status:
Activate the sensor field 'On' for several seconds while the device is in receiving mode. The LED
'Battery' goes on and the LED bar shows the battery level.
= 100%,
= 80%,
= 60%,
= 40%,
= 20%
Teach-in of the device:
Set your controller to radio channel 41 (434.075 MHz). The frequency of the PFS Profi can only be
changed by the manufacturer. Receiver is switched off. Activate sensor field 'On' and keep it activated
until the yellow LED 'Programming' goes on. Operate PFS Profi in manual firing mode and then
activate the firing mode or if PFC Advanced is being used press 'Transmit System ID' in the
corresponding submenu of the menu 'System ID Management'.
Programming of the firing channel:
Switch on the controller and select the required firing channel in the manual firing mode. Receiver is in
normal operation mode (receiving mode). Activate the sensor field 'On' until the yellow LED
'Programming' goes on. Press the button 'Range Test' at the PFS Profi or 'Wireless Programming' at
the PFC Advanced.
Range test:
Start the test at your controller. The LED 'Range Test' goes on and the test result is being displayed
on the led bar:
= 90%,
= 70%,
= 50%,
= 30%,
= 10%
Continuity test:
LED 'Output' is on for a long period of time = firing line is open, no continuity
LED 'Output' is on for a short period of time = firing line has continuity
Low battery indicator:
If the battery level is less than 30% the LED 'Battery' begins to flash as a warning signal.
Firing power and firing parameters:
max. 10 e-matches of type 'A' or 'U' in series connection
max. 10 e-matches of type 'A' or max. 5 e-matches of type 'U' in parallel connection
Maximum resistance if e-matches of type 'A' are being used in series connection: 20 Ohms
Maximum resistance if e-matches of type 'U' are being used in series connection: 10 Ohms
Firing voltage: approx. 20 Volts
Maximum operation time: 20 h
Firing: LED 'Output' is lit in red color, device automatically powers down immediately after firing
Protect the device against moisture. Read the user manual completely and mind all safety
regulations.
17