Autonics KRN1000 Series Руководство по эксплуатации - Страница 2

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Измерительные приборы Autonics KRN1000 Series. Autonics KRN1000 Series 2 страницы. Lcd touchscreen paperless recorder
Также для Autonics KRN1000 Series: Руководство по эксплуатации (2 страниц), Руководство пользователя (15 страниц)

Autonics KRN1000 Series Руководство по эксплуатации
Status Display Part
1
2
3
4
5
6
Section
Item
Description
Menu
Displays menu.
1
Esc
Moves from menu to current screen.
Home
Moves to main screen.
Displays currently displayed group name.
2
Group
Touch the icon and select the group. You can set the group name and the set
group name is displayed.
Select the displayed graph at the current screen.
3
Graph
Select one among bar graph, vertical/horizontal trend graph, divided vertical/
horizontal trend graph, vertical/horizontal mixed graph, digital group/all.
Displays at standard user mode.
Lock
(activated log-in function or log off status)
Displays at administer mode.
Lock Setting
(activated log-in function and log-in as administer mode)
Displays at unlock.
Unlock
4
(inactivated log-in function)
No Alarm
Displays at no alarm.
Alarm
Displays when alarm occurs.
Internal Memory
Displays when displaying measurement value and no recording it at internal
Record
memory.
5
Internal Memory
Displays usage details of data recording space.
No Record
Data Record Space
Displays usage details of data recording space.
6
Alarm Record Space
Displays empty space of alarm data memory.
Event Record Space
Displays empty space of event data memory.
USB Memory
Displays when USB memory is not connected.
No Connection
USB Memory No Save
Displays when internal memory data does not save at USB memory.
(gray)
USB Memory Save
Displays when internal memory data saves at USB memory.
(yellow)
7
SD Card
Displays when SD card is not connected.
No Connection
SD Card No Save
Displays when internal memory data does not save at SD card.
(gray)
SD Card Save
Displays when internal memory data saves at SD card.
(yellow)
Displays date and time.
8
Date/Time
If summer time is set, "(s)" marks in front of time.
Menu
Display
History
System Info.
File History
Group Setting
Touch Calibration
Status
Alarm List
Event List
AO/DI Status
Memory Info.
Input CH Info.
Input/Display
Input Option
Screen Capture
Alarm
Log OFF/Power OFF
User Unit
Option Info.
Alarm Output
Digital Input
RS422/485
Ethernet/USB
※For more information about menu, refer to KRN1000 user manual.
Major Menu
1) Input/Display
[Menu → Input CH Info. → Input/Display]
It sets input type of each channel of KRN1000.
7
8
1
2
3
4
5
6
No
Item
1
Channel
2
Copy
3
Input Type
Low-Limit Graph Scale/
4
Low-Limit Input
High-Limit Graph Scale/
5
High-Limit Input
6
Point
7
Tag Name
8
Low-Limit Scale
9
High-Limit Scale
10
Display Unit
2) Device
[Menu → System Info. → Device]
It sets initial setting and option of KRN1000.
1
2
7
3
4
5
No
Item
Descriptions
Set KRN1000 device name.
1
Device Name
Date/Time
It supports English capital/small letter, sign and number up to 16 characters.
Set KRN1000 display language.
Reservation
2
Language
It supports Korean, English, Chinese (Simplified/Traditional) and Russian.
Device
Set record status when supplying power or re-supplying power at power failure.
- Hold: It maintains record status (recording/stop) of before power OFF.
File
3
PWR ON Record
- Record: It records when power is ON.
- Stop: It does not record regardless when power is ON.
Log In
Set touch sound volume when touching the menu or button of screen.
4
Touch Sound
System Info.
Setting range: OFF, Min., Standard, Max.
Set alarm sound volume.
5
Alarm Sound
Memory Management
Setting range: OFF, Min., Standard, Max.
Set internal sampling period of measurement value.
Internal Memory
Setting range (varied by number of input channel connections)
6
Sampling
- Below 4CHs: 25, 125, 250ms
- The others: 125, 250ms
Set log speed for recording measurement value at system memory.
Log Record
7
Setting range: 1 to 3600 sec
Speed
E.g.) When setting as 3 sec, it records present value and the value after 3 sec.
Set Graph speed for displaying data on the graph.
8
Graph Speed
Setting range: 1 to 3600 sec
E.g.) When setting as 3 sec, new data is displayed on the graph with the interval of 3 sec.
Set display backlight level.
9
Backlight
Setting range: Min., Standard, Max.
For saving LCD life cycle and power, screen can automatically turn OFF.
10
Screen Save
Even though during screen save status, it maintains recording. Touch the screen and it turn ON the screen.
Setting range: 0 to 360 min (0: disable screen save)
7
8
9
10
Descriptions
Moves channel. Touch 'CH1' or
to change the channel.
Copies the other channels parameters of the same group. Select the channel to be copy.
Set the input type. Input types are total 27: thermocouple, RTD, voltage, current (shunt).
In case of temperature sensor input, set the low-limit graph scale value within the input range.
Setting range: Min. value of input range to high-limit graph scale value-F.S. 5%
E.g.) In case of TC-K input, -200.0 to 1350.0℃ of input range, and setting range is -200.0 to 1272.5℃.
(-F.S.=77.5)
In case of analog input, it displays low-limit input value.
In case of temperature sensor input, set the high-limit graph scale value within the input range.
Setting range: Low-limit graph scale value+F.S. 5% to Max. value of input range
E.g.) In case of TC-K input, -200.0 to 1350.0℃ of input range, and setting range is -122.5 to 1350℃.
(+F.S.=77.5)
In case of analog input, it displays high-limit input value.
- Temperature sensor input: 0, 0.0 (set the decimal point for the measurement value)
- Analog input: 0, 0.0, 0.00, 0.000, 0.0000 (set the decimal point position for the scale value)
Set the channel name.
Set the desired display value based on the measurement value.
It is activated only for analog (voltage, current (shunt)) input type.
- Temperature sensor input: Temperature units, ℃, ℉, K are available.
- Analog input: 72 display units are available. When not using unit, select blank.
6
8
9
10
3) File
[Menu → System Info. → File]
It manages parameter setting files which are saved at KRN1000 memory, resets parameters.
1
2
3
4
5
6
No
Item
Descriptions
Parameter
1
Displays parameter setting file name.
Setting File
2
Internal Memory
3
SD Memory
Save the set parameter information at the dedicated memory or open it.
4
USB Memory
5
Reset Parameters
Reset parameter settings as factory default.
Execute simulation the set parameters.
Screen Simulation
6
Touch 'Start' and re-boot the unit and simulation mode starts.
(Demo)
Touch 'Stop' to exit simulation mode and re-boot the unit.
4) Memory Management [Menu → Memory Info. → Memory Management]
It manages internal/external memory. You can check memory usage and move and copy data files.
1
2
3
4
5
No
Item
Descriptions
1
Internal Memory
Displays each memory usage.
2
SD Memory
Touch 'Clear' to initial the memory.
3
USB Memory
4
Move/Copy
Moves/Copies files of internal memory to SD/USB memory.
- Move: Moves the file to external memory and deletes the existing file at internal memory.
- Copy: Moves the file to external memory and maintains the existing file at internal memory.
- Delete: Deletes the file.
- Move All: Moves all files to external memory and deletes the existing all files at internal memory.
- Copy All: Moves all files to external memory and maintains the existing all files at internal memory.
- Delete All: Deletes all files.
5
Storage
Select the memory to save the data.
Cautions during Use
1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
2. Install a surge absorber at each end of inductive load coil when controlling high-capacity power relay or inductive load (e.g. magnet).
3. 24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
4. Check the polarity of the terminals before wiring the temperature sensor.
For RTD temperature sensor, wire it as 3-wire type, using cables in same thickness and length.
For thermocouple (CT) temperature sensor, use the designated compensation wire for extending wire.
5. Keep away from high voltage lines or power lines to prevent inductive noise.
In case installing power line and input signal line closely, use line filter or varistor at power line and shielded wire at input signal line.
Do not use near the equipment which generates strong magnetic force or high frequency noise.
6. Install the unit straightly at the well-ventilated environment with 30mm of separation distance from the wall.
7. This unit may be used in the following environments.
①Indoors (in the environment condition rated in 'Specifications') ②Altitude max. 2,000m
③Pollution degree 2
④Installation category II