Initial and Periodic Testing of the System
It is important that initial and periodic (monthly) testing of the system be
conducted to ensure continued protection against sudden and accidental
plumbing fl ooding.
Maintenance Procedure: Approx. _____ min./mo.
1. Verify that the Leak Stop
outlet and powered up.
2. Verify the Leak Stop
(GREEN light illuminated).
3. Using a wet cloth, so as to not disturb adhesive (do not use distilled or
RO water), saturate sensor to activate valve closure.
4. The sensor will detect the water and the Leak Stop
the CLOSED position.
5. Verify the Leak Stop
(RED light illuminated).
If Leak Stop
closure of the valve by then opening any downstream hot water faucet
in the home as if you were drawing hot water. As the residual water in the
pipe runs out, you will notice a slowing of fl ow and fi nally a stoppage of
water. YOU MUST TEST A HOT WATER FAUCET. Testing a cold water
faucet will not return an accurate result.
If Leak Stop
fl ow has stopped by attempting to draw water from that device.
6. Remove the sensor from the water and dry thoroughly. Remember to close
any dry faucets you may have opened during testing.
7. Press the GREEN button on the Leak Stop
valve and restore water supply.
8. Repeat steps 2 through 7 for the second sensor.
9. Test buttons.
+
valve is plugged into a standard grounded
+
valve is in the OPEN position
+
valve is in the CLOSED position
+
is installed on a water heater, you can additionally test
+
is installed on any other water appliance, verify that outlet
+
valve will cycle to
+