Autonics FX4Y-I4 Руководство - Страница 3
Просмотреть онлайн или скачать pdf Руководство для Таймер Autonics FX4Y-I4. Autonics FX4Y-I4 6 страниц. Din w72xh36mm of counter/timer with indication only
FXY Series
Input Connections
Voltage input (PNP)
● Solid-state input (standard sensor: PNP output type sensor)
Sensor
Brown
Black
※
Blue
(PNP output)
※ CP1, CP2 (INHIBIT), RESET input part
No-voltage input (NPN)
● Solid-state input (standard sensor: NPN output type sensor)
Sensor
Brown
Black
※
Blue
(NPN output)
※ CP1, CP2 (INHIBIT), RESET input part
Counting & Time Operation
Counting operation
● Input mode: Up
RESET
+Max. display value
0
● Input mode: Up/Down-A, B, C
RESET
+Max. display value
0
-Max. display value
Time operation
● Up mode
RESET
INHIBIT
+Max. display value
0
J-38
Counter/Timer
Sensor
+12V
Inner circuit
10.8kΩ
0V
(PNP open collector output)
Counter/Timer
Sensor
+12V
5.4kΩ
Inner circuit
0V
(NPN open collector output)
Counter/Timer
Brown
+12V
Black
Inner circuit
※
10.8kΩ
Blue
0V
Counter/Timer
Brown
+12V
5.4kΩ
Black
Inner circuit
※
Blue
0V
● Input mode: Down
RESET
+Max. display value
0
-Max. display value
● Input mode: Up/Down-D, E, F
RESET
+Max. display value
0
-Max. display value
● Down mode
RESET
INHIBIT
+Max. display value
0
-Max. display value
● Contact input
Counter/Timer
※
+12V
Inner circuit
10.8kΩ
0V
※ Counting speed
: Set as 1 or 30cps
● Contact input
Counter/Timer
+12V
5.4kΩ
※
Inner circuit
0V
※ Counting speed
: Set as 1 or 30cps