Flood Sensor Battery Life
WaterCopPRO wireless sensors require power to operate.
Use either fresh AA alkaline batteries (not included) and/
or a WaterCopPRO Sensor AC Adaptor (sold separately)
to power. If both are used, batteries will provide back-up
power in the event AC is lost. Rechargeable batteries are
not recommended.
Operating the WaterCopPRO System
The normal position of the valve is open to allow full flow
throughout the plumbing system. WaterCopPRO is a full
port ball valve which does not restrict the flow capacity of
your plumbing system. The indicator lights on the face of
the WaterCopPRO will show the position of the valve.
If the valve is in the CLOSED position (the red light will be
lit), press OPEN and the valve will move to the open position
(green indicator will light).
When leaking water comes into direct contact with a flood
sensor, an RF (radio frequency) signal is transmitted to
the WaterCopPRO and the valve closes, turning off the
water source to protect the building from additional water
damage.
The red indicator light will signal that the valve is now in
the CLOSED position. The valve will remain closed until the
unit is manually reset. After the plumbing problem is fixed,
reset the WaterCopPRO by pressing OPEN VALVE (green
circle) on the face of the WaterCopPRO actuator. Valve will
open and green indicator will be lit.
Note: If major repairs are needed to correct the plumbing
system, it is recommended that the manual shut-off valve
upstream of the WaterCopPRO also be closed during the
repairs. Close the main water shut-off valve and unplug
the WaterCopPRO before making repairs on the plumbing
system.
Note: In case of a power failure, use the manual shut-off
valve to turn the water off in case of an emergency. When
power is restored, the WaterCopPRO will remain in its last
known position indicated by the red or green lights on the
face of the unit.
WaterCopPRO Specifications
Max. working pressure .... 125 PSIG
Ambient temperature ....... 35° to 105°F
Enclosure............................ Polycarbonate NEMA 4
Voltage ................................ 12 VDC includes 120 VAC adaptor
Current ................................ 1.3 Amps
Valve.................................... Full-Port, ANSI NSF 372
Valve seals ......................... RTFE (Reinforced Teflon)
FCC Information
This equipment has been tested and found to comply with
Sensor can be placed
under dishwasher or
near the water lines
the limits for a class B digital device, pursuant to part 15
underneath the
kitchen sink
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses
and can radiate radio frequency energy and if not installed
and used in accordance with the instructions, may cause
harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiver.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
• Consult the dealer for help.
Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must
accept any interference, including interference that may
cause undesired operation of the device.
The user is cautioned that changes and modification made
to the equipment without the approval of the manufacturer
could void the user's authority to operate this equipment.
LIMITED WARRANTY
DynaQuip Controls Corporation warrants the electrical
components of the WaterCopPRO System to be free from
defects in material and workmanship under normal use and
if properly installed for a period of two years from the date
of purchase.
3
approved, Lead-Free Brass, NPT