Choose a dry location to install the WaterCop . ® The front control panel should be easily
visible in order to see what position the valve is in (open/closed) and accessible for
resetting after a leak has been detected and corrected, and for checking and resetting the
radio receiver code if necessary . Place the valve where the housing is protected from use
as a step or other excessive loads . The shut-off valve must be installed:
In the main water line;
Just downstream from the main water shut-off valve;
In a dry location (indoors only);
Where it is accessible for checking and resetting the valve and for resetting the
radio receiver code, if necessary; and
Where the case is protected from use as a step or other excessive loads .
CAUTION:
tightening fittings. Use a wrench on the valve flats that are provided.
CAUTION:
or motor housing. Proper precautions should be taken to prevent damage
from heat when installing the unit. Remove plastic housing before
soldering valve in place.
WARNING:

Mounting Actuator to Valve

1 . Make sure the valve and motor box are both in the OPEN position .
a . The slot in the valve stem should be in line with the valve body, end to end .
b . Apply power to the control box . The green light should be ON . If not press the
green button and the unit will cycle to the OPEN position . Disconnect power .
2 . Place the spring clip around neck of the valve as shown .
3 . Place O-ring into valve mounting recess .
4 . Slide the valve on to the mounting pins
in the position shown .
IMPORTANT: The control box must
be aligned with the valve as shown .
5 . Secure by compressing the spring
clip and sliding it to the inside of the
mounting pins .
6 . Release clip . Make sure the clip is
inserted into the groove in all four
mounting pins .
14
Never use the housing for leverage when mounting this unit or
High heat from soldering or brazing can damage valve seats
Do not use on fire sprinkler systems.
Spring Clip
O-Ring
Mounting Pins
Control Box
Valve