Ordering Information
This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.
LE4S ❶
❶ Output
No mark: Time limit 1c
A: Time limit 2c, Time limit 1c + Instantaneous 1c
Product Components
• Product
(+ bracket)
Dimensions
• Unit: mm, For the detailed drawings, follow the Autonics website.
□52
6
□48
2
■ Bracket
30.5
□49.5
60.3
Unit Descriptions
1
3
2
5
6
7
4
8
9
10
11
No.
Name
1
Time progressing display part
2
Time setting display part
3
Time unit
4
Operation mode
5
Output contact
6
UP / DOWN
7
Key lock
8
[RST] key
9
[MD] key
10
[◀] key
11
[▲] key
Mode Setting
Parameter setting
[MD] 3 sec
Time setting
[◀]
RUN
Check output
While pressing [MD]
contact status
[RST]
01) If no key is pressed over 60 sec, returning to RUN mode and not storing the setting value.
02) Only for the LE4SA model
• Instruction manual
56
14
■ Panel cut-out
≥ 65
□45
+ 0.5
0
Function
Shows progressing time
Shows the setting time
Shows time unit (h: hour / m: min / s: sec)
Flashing: time progressing
Shows current output operation mode
• INTG: no mark
Shows the status of current output contact
Shows UP / DOWN mode of time progressing
Shows key lock status
Initializes progressing time and output return
Enter RUN mode ↔ Parameter setting
Shift to next parameter in parameter setting
Enter RUN mode ↔ setting time change mode
Move the digit when changing the setting value.
Change the parameter setting value
[MD] 3 sec
[MD]
01)
Release [MD]
02)
Initialization
Auto
Output Operation Mode
For the detailed timing chart for operation output mode, refer to the manual.
The output operation mode differs depending on each model.
Group
Output operation mode
OND
OND.1
OND.2
Group 1
INT
INT.1
OFD
INTG
FLK
FLK.1
Group 2
NFD
NFD.1
S-D
Group 3
TWN
TWN.1
Parameter Setting
• Some parameters are activated / deactivated depending on the model or setting of
other parameters. Refer to the description of each parameter.
• In the parameter setting, the time and output control continue.
• If the settings are changed, all outputs to be OFF and reset the current values when
returning to RUN mode.
• [MD] key: saves current setting value and moves to the next parameter.
Parameter
Display
Output
1-1
operation
OUtM
mode
1-2
Time range
tRNG
One-shot
1-3
output
OUTt
time
T.off
1-4
time range
OfRG
T.on
1-5
time range
OnRG
T1
1-6
time range
T!RG
T2
1-7
time range
T@RG
Time
1-8
UP / DOWN
Width of
1-9
min. input
signal
Output
1-10
contact
01)
CONT
1-11 Backlight
1-12 Key lock
LOCK
01) 1-1. Output operation mode of group 3: 2C fixed
• [Table]
Unit
SEC
SEC
Display
9.999
99.99
0.001s to
0.01s to
Range
9.999s
99.99s
Unit
H M
H
Display
99h59m
99.99h
0h1m to
0.01h to
Range
99h59m
99.99h
RUN
LE4S
LE4SA
ON Delay
ON Delay 1
-
ON Delay 2
Interval
Interval 1
OFF Delay
-
Integration time
Flicker
Flicker 1
ON - OFF Delay
-
ON - OFF Delay 1
Star - Delta
Twin
-
Twin 1
Defaults Setting range
• Refer to the output
operation mode.
OND
• Refer to the table
below.
9(99
0)50 0.01 to 99.99 sec
9(99
• Refer to the table
9(99
below.
9(99
9(99
UP: 0 → setting time
DN: setting time → 0
U-D
UP
1, 20 ms
• Set the min. width of
RESET, START, INHIBIT
InT
20
input signals
1C.1C: Time limit 1c +
Instantaneous 1c
1c1C
2C: Time limit 2c
ON ON, OFF
BLU
L.OFF: release key lock
LOC.1: lock [RST] key
lOFF
LOC.2: lock [◀], [▲] key
LOC.3: lock [RST], [◀],
[▲] key
LOc1
SEC
SEC
M S
M
999.9
9999
99m59s
999.9m
0.1s to
1s to
0m1s to
0.1m to
999.9s
9999s
99m99s
999.9m
H
H
999.9h
9999h
0.1h to
1h to
999.9h
9999h
Time setting
Time
tOFF, tON
OnD, OFfD
T-1, T-2
Display
Model
condition
-
1-1. Output
operation
mode: Group 1
1-1. Output
Comm.
operation
mode: OND.2
1-1. Output
operation
mode: Group 2
[LE4SA] 1-1. Output
operation
mode: Group 3
[LE4SA]
Comm.
-
[LE4S]
-
[LE4SA] -
Comm.
-
[LE4S]
-
[LE4SA]
M
9999m
1m to
9999m